<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>TCTempX Archives | Instrumentation Engineering Services Ltd.</title>
	<atom:link href="https://ieslbd.com/product-tag/tctempx/feed/" rel="self" type="application/rss+xml" />
	<link>https://ieslbd.com/product-tag/tctempx/</link>
	<description>Accredited calibration laboratory, accredited inspection body and instrument supplier</description>
	<lastBuildDate>Tue, 28 Oct 2025 12:14:40 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://ieslbd.com/wp-content/uploads/2021/04/icon-150x150.png</url>
	<title>TCTempX Archives | Instrumentation Engineering Services Ltd.</title>
	<link>https://ieslbd.com/product-tag/tctempx/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TCTempX</title>
		<link>https://ieslbd.com/service/tctempx/</link>
					<comments>https://ieslbd.com/service/tctempx/#respond</comments>
		
		<dc:creator><![CDATA[Md. Yousuf]]></dc:creator>
		<pubDate>Tue, 28 Oct 2025 12:14:40 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12509</guid>

					<description><![CDATA[<p>The MadgeTech TCTempX is a versatile, multi-channel thermocouple-based temperature data logger available in 4-, 8-, 12-, and 16-channel configurations. It supports thermocouple types J, K, T, E, R, S, B, and N, with a temperature range up to 1820 °C, depending on the probe used. The device features individual cold junction compensation for each channel, ensuring accurate measurements. With a memory capacity of up to 524,032 readings per channel and a typical battery life of 18 months, it's ideal for applications requiring simultaneous monitoring of multiple temperature points.</p>
<p>The post <a href="https://ieslbd.com/service/tctempx/">TCTempX</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The TCTempX Series includes 4, 8, 12, and 16-channel thermocouple-based temperature data loggers. Includes ISO17025 accredited calibration certificate.</p>
<p>Key Features:</p>
<ul>
<li style="list-style-type: none;">
<ul>
<li>Accepts a Variety of Thermocouples</li>
<li>Large Memory Capacity</li>
<li>Individual Cold Junction Compensation</li>
</ul>
</li>
</ul>
<p>The TCTempX Series includes the TCTempX4, TCTempX8, TCTempX12 and TCTempX16 thermocouple-based temperature data loggers with a reading rate of up to 4 Hz, ideal for a variety of applications, whether it is remote temperature monitoring or multiple points in a central location.</p>
<p>In addition to having a large memory capacity, the TCTempX allows users to disable channels to further maximize memory capacity. For easy identification, each channel can be named with up to a ten-digit title.</p>
<p>In addition, the TCTempX Series features individual cold junction compensation for each channel providing increased accuracy and response time, and if a probe is removed or severed during logging, the software automatically annotates the data.</p>
<p>The TCTempX Series is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.</p>
<div id="" class="specs-table-wrapper">
<h2>Specifications</h2>
<h3>General</h3>
<table id="tablepress-tctempx-general-no-3" class="tablepress tablepress-id-tctempx-general">
<tbody>
<tr class="row-1">
<td class="column-1">Memory</td>
<td class="column-2">4-channel: 524,032 readings<br />
8-channel: 262,016 readings<br />
12-channel: 174,677 readings<br />
16-channel: 131,008 readings</td>
</tr>
<tr class="row-2">
<td class="column-1">Reading Rate</td>
<td class="column-2">4 Hz up to 1 reading every 24 hours</td>
</tr>
<tr class="row-3">
<td class="column-1">Cold Junction Compensation</td>
<td class="column-2">Automatic, based on internal channel</td>
</tr>
<tr class="row-4">
<td class="column-1">Channels</td>
<td class="column-2">4, 8, 12, 16</td>
</tr>
<tr class="row-5">
<td class="column-1">Battery Life</td>
<td class="column-2">18 months typical</td>
</tr>
<tr class="row-6">
<td class="column-1">Material</td>
<td class="column-2">Black anodized aluminum</td>
</tr>
<tr class="row-7">
<td class="column-1">Dimensions</td>
<td class="column-2">4-channel: 2.70 in x 7.25 in x 1.22 in<br />
(65.6 mm x 184.2 mm x 31.0 mm)<br />
8-channel: 2.70 in x 7.25 in x 1.22 in<br />
(65.6 mm x 184.2 mm x 31.0 mm)<br />
12-channel: 2.70 in x 7.25 in x 1.68 in<br />
(65.6 mm x 184.2 mm x 42.7 mm)<br />
16-channel: 2.70 in x 7.25 in x 2.14 in<br />
(65.6 mm x 184.2 mm x 54.4 mm)</td>
</tr>
<tr class="row-8">
<td class="column-1">Operating Environment</td>
<td class="column-2">-20 ºC to +60 ºC (-4 ºF to +140 ºF),<br />
0 %RH to 95 %RH non-condensing</td>
</tr>
<tr class="row-9">
<td class="column-1">Approvals</td>
<td class="column-2">CE</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<div id="" class="specs-table-wrapper">
<h3>Temperature</h3>
<table id="tablepress-tctempx-temperature-no-2" class="tablepress tablepress-id-tctempx-temperature">
<tbody>
<tr class="row-1">
<td class="column-1">Internal Channel Temperature Resolution</td>
<td class="column-2">0.01 °C (0.018 °F)</td>
</tr>
<tr class="row-2">
<td class="column-1">Remote Channel Temperature Sensor</td>
<td class="column-2">Thermocouple Types J, K, T, E, R, S, B, N</td>
</tr>
<tr class="row-3">
<td class="column-1">Remote Channel Temperature Range</td>
<td class="column-2">Thermocouple Dependent</td>
</tr>
<tr class="row-4">
<td class="column-1">Remote Channel Temperature Resolution</td>
<td class="column-2">Thermocouple Dependent</td>
</tr>
<tr class="row-5">
<td class="column-1">Remote Channel Temperature Calibrated Accuracy</td>
<td class="column-2">Thermocouple Dependent</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://ieslbd.com/service/tctempx/">TCTempX</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/tctempx/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
