<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>VFC2000-MT Archives | Instrumentation Engineering Services Ltd.</title>
	<atom:link href="https://ieslbd.com/product-tag/vfc2000-mt/feed/" rel="self" type="application/rss+xml" />
	<link>https://ieslbd.com/product-tag/vfc2000-mt/</link>
	<description>Accredited calibration laboratory, accredited inspection body and instrument supplier</description>
	<lastBuildDate>Tue, 28 Oct 2025 12:13:41 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://ieslbd.com/wp-content/uploads/2021/04/icon-150x150.png</url>
	<title>VFC2000-MT Archives | Instrumentation Engineering Services Ltd.</title>
	<link>https://ieslbd.com/product-tag/vfc2000-mt/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>VFC2000-MT</title>
		<link>https://ieslbd.com/service/vfc2000-mt/</link>
					<comments>https://ieslbd.com/service/vfc2000-mt/#respond</comments>
		
		<dc:creator><![CDATA[Md. Yousuf]]></dc:creator>
		<pubDate>Tue, 28 Oct 2025 12:13:41 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12513</guid>

					<description><![CDATA[<p>The VFC2000-MT is a low-cost, vaccine-compliant temperature monitoring system designed to meet Centers for Disease Control and Prevention (CDC) and VFC program requirements. It records ambient and remote temperatures (from as low as –100 °C / –148 °F) with a built-in LCD display, audio/visual alarms, daily check reminder, and compatibility with MadgeTech 4 software.</p>
<p>The post <a href="https://ieslbd.com/service/vfc2000-mt/">VFC2000-MT</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The VFC2000-MT is a low-cost temperature monitoring system for vaccines, recording temperatures as low as -100 °C (-148 °F). Includes ISO17025 accredited calibration certificate.</p>
<p>Key Features:</p>
<ul>
<li>VFC &amp; CDC Compliant</li>
<li>Audible &amp; Visual Alarms</li>
<li>Temperature Check Reminder</li>
<li>Annual or Biennial Calibration Option</li>
</ul>
<p>The VFC2000-MT is a simple, low-cost temperature monitoring system for vaccines. The VFC2000-MT is designed to comply with all CDC and VFC requirements and provides precise, continuous temperature monitoring and validation for temperatures as low as -100 °C (-148 °F).</p>
<p>Featuring a convenient LCD screen, the VFC2000-MT displays current, minimum, and maximum readings as well as a battery level indicator. The VFC2000-MT is also equipped with an LED reminder to conduct the required 24-hour temperature check. If temperatures fluctuate out-of-range, the VFC2000-MT triggers an audio and visual alert.</p>
<p>The VFC2000-MT is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical and tabular data is provided for analysis and can be viewed using the software which supports customizable engineering units.</p>
<h2>Specifications</h2>
<h3>General</h3>
<table id="tablepress-vfc2000-general" class="tablepress tablepress-id-vfc2000-general">
<tbody>
<tr class="row-1">
<td class="column-1">Memory</td>
<td class="column-2">16,128 readings (all channels enabled)</td>
</tr>
<tr class="row-2">
<td class="column-1">Reading Rate</td>
<td class="column-2">1 reading every second up to 1 reading every 24 hours</td>
</tr>
<tr class="row-3">
<td class="column-1">Cold Junction Compensation</td>
<td class="column-2">Automatic based on internal channel</td>
</tr>
<tr class="row-4">
<td class="column-1">Battery Life</td>
<td class="column-2">3 years typical at 1 minute reading rate</td>
</tr>
<tr class="row-5">
<td class="column-1">Material</td>
<td class="column-2">ABS Plastic</td>
</tr>
<tr class="row-6">
<td class="column-1">Dimensions</td>
<td class="column-2">3.0 in x 3.5 in x 0.95 in (76.2 mm x 88.9 mm x 24.1 mm) &#8211; Data logger only</td>
</tr>
<tr class="row-7">
<td class="column-1">Operating Environment</td>
<td class="column-2">-20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing</td>
</tr>
<tr class="row-8">
<td class="column-1">Required Interface Package</td>
<td class="column-2">USB to Mini USB Cable</td>
</tr>
<tr class="row-9">
<td class="column-1">Weight</td>
<td class="column-2">1.1250 LBS</td>
</tr>
<tr class="row-10">
<td class="column-1">Baud Rate</td>
<td class="column-2">250,000</td>
</tr>
</tbody>
</table>
<h3>Temperature</h3>
<table id="tablepress-vfc2000-temperature" class="tablepress tablepress-id-vfc2000-temperature">
<tbody>
<tr class="row-1">
<td class="column-1">Internal Channel Temperature Sensor</td>
<td class="column-2">Semiconductor</td>
</tr>
<tr class="row-2">
<td class="column-1">Internal Channel Temperature Range</td>
<td class="column-2">-20 °C to 60 °C (-4 °F to +140 °F)</td>
</tr>
<tr class="row-3">
<td class="column-1">Internal Channel Temperature Resolution</td>
<td class="column-2">0.01 °C (0.18 °F)</td>
</tr>
<tr class="row-4">
<td class="column-1">Internal Channel Temperature Calibrated Accuracy</td>
<td class="column-2">±0.5 °C (0 °C to +50 °C)</td>
</tr>
<tr class="row-5">
<td class="column-1">Remote Channel Temperature Sensor</td>
<td class="column-2">Type K Thermocouple (Included)</td>
</tr>
<tr class="row-6">
<td class="column-1">Remote Channel (Thermocouple) Temperature Range</td>
<td class="column-2">-100 °C to +80 °C (-148 °F to +176 °F)</td>
</tr>
<tr class="row-7">
<td class="column-1">Remote Channel (Glycol Bottle) Temperature Range</td>
<td class="column-2">-50 °C to +80 °C (-58 °F to +176 °F)</td>
</tr>
<tr class="row-8">
<td class="column-1">Remote Channel Temperature Resolution</td>
<td class="column-2">0.1 °C (0.18 °F)</td>
</tr>
<tr class="row-9">
<td class="column-1">Remote Channel Temperature Calibrated Accuracy</td>
<td class="column-2">±0.5 °C</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://ieslbd.com/service/vfc2000-mt/">VFC2000-MT</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>