<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Wireless Thermal Validation Archives | Instrumentation Engineering Services Ltd.</title>
	<atom:link href="https://ieslbd.com/product-tag/wireless-thermal-validation/feed/" rel="self" type="application/rss+xml" />
	<link>https://ieslbd.com/product-tag/wireless-thermal-validation/</link>
	<description>Accredited calibration laboratory, accredited inspection body and instrument supplier</description>
	<lastBuildDate>Mon, 20 Oct 2025 18:41:18 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://ieslbd.com/wp-content/uploads/2021/04/icon-150x150.png</url>
	<title>Wireless Thermal Validation Archives | Instrumentation Engineering Services Ltd.</title>
	<link>https://ieslbd.com/product-tag/wireless-thermal-validation/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Temperature Verification Software Power 3000</title>
		<link>https://ieslbd.com/service/temperature-verification-software-power-3000/</link>
					<comments>https://ieslbd.com/service/temperature-verification-software-power-3000/#respond</comments>
		
		<dc:creator><![CDATA[IESLBD]]></dc:creator>
		<pubDate>Mon, 20 Oct 2025 18:40:34 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12362</guid>

					<description><![CDATA[<p>calibration, verify, Report, Compliance and Security</p>
<p>The post <a href="https://ieslbd.com/service/temperature-verification-software-power-3000/">Temperature Verification Software Power 3000</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong><span dir="auto">Temperature Verification Software Power 3000</span></strong></p>
<p>&nbsp;</p>
<p><strong><span dir="auto">calibration</span></strong></p>
<p><span dir="auto">● Multi-point calibration, single-point or multi-point calibration can be achieved</span></p>
<p><span dir="auto">● Various wired calibration modes, including manual or manual + automatic mixed calibration</span></p>
<p><span dir="auto">● In the fully automatic calibration mode, it can automatically communicate with the probe or dry well to automatically complete the calibration</span></p>
<p><span dir="auto">● Support multi-stage compensation and calibration of wireless recorders</span></p>
<p><span dir="auto">● With post-verification function</span></p>
<p><strong><span dir="auto">verify</span></strong></p>
<p>&nbsp;</p>
<p><span dir="auto">● Supports three types of verification: temperature, humidity, and pressure. The verification channel can be expanded infinitely</span></p>
<p><span dir="auto">● Support wired, wireless, and hybrid (wired + wireless) authentication methods</span></p>
<p><span dir="auto">● Support multiple verification start and stop methods</span></p>
<p><span dir="auto">● Can run verification on multiple devices in real time, with no limit on the number of verifications</span></p>
<p><span dir="auto">● Wired verification can observe verification data in real time: trend chart, kill rate calculation, temperature statistics calculation, etc.</span></p>
<p><span dir="auto">● During wireless verification, you can close the software after running it in the background</span></p>
<p><strong><span dir="auto">Report</span></strong></p>
<p>&nbsp;</p>
<p><span dir="auto">● Both calibration and verification can generate original unchangeable calibration data and verification data</span></p>
<p><span dir="auto">● Calibration data can be split into multiple reports as needed</span></p>
<p><span dir="auto">● Verification data can be divided into multiple cycles and multiple stages</span></p>
<p><span dir="auto">● Report content can be flexibly filtered to display important information</span></p>
<p><span dir="auto">● Different parameters can be set to calculate F0 value, FH value, A0 value, etc.</span></p>
<p><span dir="auto">● Calculate cold spots, hot spots, uniformity, fluctuation, etc.</span></p>
<p><span dir="auto">● The verification report calculation content is comprehensive and rich, meeting different calculation needs</span></p>
<p><span dir="auto">● Calibration or verification data can be backed up and restored separately</span></p>
<p><span dir="auto">● Can output files in different formats such as PDF, CSV, Excel, etc.</span></p>
<p><span dir="auto">● Detailed report filtering capabilities</span></p>
<p><strong><span dir="auto">Compliance and Security</span></strong></p>
<p>&nbsp;</p>
<p><span dir="auto">● Comply with FDA 21CFR Part 11 requirements for electronic records, audit trails and electronic signatures</span></p>
<p><span dir="auto">● Comply with EU EN554:1994 on the validation and routine control requirements of moist heat sterilization of medical devices</span></p>
<p><span dir="auto">● Level 3 user management authority</span></p>
<p><span dir="auto">● Audit trail, detailed log tracking records can be used to check every step of the user&#8217;s actions</span></p>
<p><span dir="auto">● Detailed log filtering function, convenient for viewing operation records</span></p>
<p><span dir="auto">● Safely back up data offsite</span></p>
<p>The post <a href="https://ieslbd.com/service/temperature-verification-software-power-3000/">Temperature Verification Software Power 3000</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/temperature-verification-software-power-3000/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Instrument Box</title>
		<link>https://ieslbd.com/service/instrument-box/</link>
					<comments>https://ieslbd.com/service/instrument-box/#respond</comments>
		
		<dc:creator><![CDATA[IESLBD]]></dc:creator>
		<pubDate>Mon, 20 Oct 2025 17:19:54 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12333</guid>

					<description><![CDATA[<p><strong><span dir="auto">Product Overview</span></strong></p>
<p><span dir="auto">The instrument case can be used to place the laptop, wireless recorder, reader and accessories for easy carrying.</span></p>
<p>The post <a href="https://ieslbd.com/service/instrument-box/">Instrument Box</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="prod_gs" class="prod_gs" data-type="block">
<div class="prod_view_name">
<h1><span id="ShoveWebControl_Text3"><span dir="auto">Instrument Box</span></span></h1>
</div>
<div id="prod_view_ms" class="prod_view_ms">
<p><strong></p>
<p><span dir="auto">Key Features</span></strong></p>
<p><span dir="auto">● Compact size</span></p>
<p><span dir="auto">● Strong and durable</span></p>
<p><span dir="auto">● Reasonable layout, the whole system can be placed in one instrument box</span></p>
</div>
</div>
<div class="cle"></div>
<p>The post <a href="https://ieslbd.com/service/instrument-box/">Instrument Box</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/instrument-box/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Insulated Box</title>
		<link>https://ieslbd.com/service/insulated-box/</link>
					<comments>https://ieslbd.com/service/insulated-box/#respond</comments>
		
		<dc:creator><![CDATA[IESLBD]]></dc:creator>
		<pubDate>Mon, 20 Oct 2025 17:15:58 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12331</guid>

					<description><![CDATA[<p><strong><span dir="auto">Product Overview:</span><br />
</strong><span dir="auto">When performing temperature verification in dry heat sterilizers and tunnel ovens, and the operating environment of the wireless recorder exceeds 150°C, it provides temperature protection for the recorder body.</span></p>
<p>The post <a href="https://ieslbd.com/service/insulated-box/">Insulated Box</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="prod_gs" class="prod_gs" data-type="block">
<div class="prod_view_name">
<h1><span id="ShoveWebControl_Text3"><span dir="auto">Insulated Box</span></span></h1>
</div>
<div id="prod_view_ms" class="prod_view_ms">
<p><strong></p>
<p><span dir="auto">Main features</span><br />
</strong><span dir="auto">● </span><span dir="auto">Can protect the wireless recorder at 400℃ for 30min</span><br />
<span dir="auto">● </span><span dir="auto">Small size</span><br />
<span dir="auto">● </span><span dir="auto">Easy to take and put the recorder</span></p>
</div>
</div>
<div class="cle">
<table class="ueditorTableStyle" width="611" cellspacing="0">
<tbody>
<tr class="firstRow">
<td valign="top" width="215"><strong><span dir="auto">model</span></strong></td>
<td valign="top" width="209"><strong><span dir="auto">SWL-TBR1-40030 </span></strong><span dir="auto"><strong>small</strong></span><strong> </strong></td>
<td valign="top" width="187"><strong><span dir="auto">WL-TBR1-40030 </span></strong><span dir="auto"><strong>medium</strong></span><strong> </strong></td>
</tr>
<tr>
<td valign="center" width="215"><span dir="auto">Temperature range</span></td>
<td colspan="2" valign="center" width="396"><span dir="auto">Protect the recorder at</span><span dir="auto"> 400℃ for </span><span dir="auto">25</span><span dir="auto"> minutes</span></td>
</tr>
<tr>
<td valign="center" width="215"><span dir="auto">Shell material</span></td>
<td colspan="2" valign="top" width="396"><span dir="auto">Stainless steel 304</span></td>
</tr>
<tr>
<td valign="center" width="215"><span dir="auto">Liner material</span></td>
<td colspan="2" valign="top" width="396"><span dir="auto">Aluminum alloy 6061</span></td>
</tr>
<tr>
<td valign="center" width="215"><span dir="auto">color</span></td>
<td colspan="2" valign="top" width="396"><span dir="auto">Silvery white</span></td>
</tr>
<tr>
<td valign="center" width="215"><span dir="auto">Dimensions (length x width x height)</span></td>
<td colspan="2" valign="top" width="396"><span dir="auto">149.8ⅹ81.4ⅹ61.4mm</span></td>
</tr>
<tr>
<td valign="center" width="215"><span dir="auto">quality</span></td>
<td valign="top" width="209"><span dir="auto">1500g</span></td>
<td valign="top" width="187"><span dir="auto">1480g</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://ieslbd.com/service/insulated-box/">Insulated Box</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/insulated-box/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Freeze dryer heat conduction block</title>
		<link>https://ieslbd.com/service/freeze-dryer-heat-conduction-block/</link>
					<comments>https://ieslbd.com/service/freeze-dryer-heat-conduction-block/#respond</comments>
		
		<dc:creator><![CDATA[IESLBD]]></dc:creator>
		<pubDate>Mon, 20 Oct 2025 17:13:01 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12329</guid>

					<description><![CDATA[<p><strong><span dir="auto">Product Overview</span></strong></p>
<p><span dir="auto">The freeze dryer heat conduction block provides fixation and heat conduction for the probe of the wireless recorder when performing freeze dryer temperature verification.</span></p>
<p>The post <a href="https://ieslbd.com/service/freeze-dryer-heat-conduction-block/">Freeze dryer heat conduction block</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="prod_view_name">
<h1><span id="ShoveWebControl_Text3"><span dir="auto">Freeze dryer heat conduction block</span></span></h1>
</div>
<div id="prod_view_ms" class="prod_view_ms">
<p><strong></p>
<p></strong><strong><span dir="auto">Key Features</span><br />
</strong></p>
<p><span dir="auto">High thermal conductivity</span></p>
<p><span dir="auto">● </span><span dir="auto">Compact size</span></p>
<p><span dir="auto">● </span><span dir="auto">Quick operation</span></p>
<table class="ueditorTableStyle" width="618" cellspacing="0">
<tbody>
<tr class="firstRow">
<td valign="center" nowrap="nowrap" width="86"><strong><span dir="auto">model</span></strong></td>
<td valign="center" nowrap="nowrap" width="86"><strong><span dir="auto">FD-HTB-SWL</span></strong></td>
<td valign="center" nowrap="nowrap" width="86"><strong><span dir="auto">FD-HTB-SWL-L</span></strong></td>
<td valign="center" nowrap="nowrap" width="86"><strong><span dir="auto">FD-HTB-WL</span></strong></td>
<td valign="center" nowrap="nowrap" width="86"><strong><span dir="auto">FD-HTB-WL-L</span></strong></td>
<td valign="center" nowrap="nowrap" width="86"><strong><span dir="auto">FD-HTB-B</span></strong></td>
</tr>
<tr>
<td valign="center" width="86"><span dir="auto">Probe hole diameter</span></td>
<td colspan="4" valign="center" nowrap="nowrap" width="72"><span dir="auto">Φ2.7mm</span></td>
<td valign="center" nowrap="nowrap" width="86"><span dir="auto">Φ3.2mm</span></td>
</tr>
<tr>
<td valign="center" width="86"><span dir="auto">Dimensions (diameter </span><span dir="auto">x height)</span></td>
<td valign="center" nowrap="nowrap" width="86"><span dir="auto">23×13.5×60</span></td>
<td valign="center" nowrap="nowrap" width="86"><span dir="auto">23×13.5×190</span></td>
<td valign="center" nowrap="nowrap" width="86"><span dir="auto">29×16×65</span></td>
<td valign="center" nowrap="nowrap" width="86"><span dir="auto">29×16×195</span></td>
<td valign="center" nowrap="nowrap" width="86"><span dir="auto">23×14.5×60</span></td>
</tr>
<tr>
<td valign="center" width="86"><span dir="auto">Surface treatment</span></td>
<td colspan="5" valign="center" nowrap="nowrap" width="90"><span dir="auto">Gold plating for rust prevention</span></td>
</tr>
<tr>
<td valign="center" width="86"><span dir="auto">Material</span></td>
<td colspan="5" valign="center" nowrap="nowrap" width="90"><span dir="auto">Copper gold plating</span></td>
</tr>
<tr>
<td valign="center" width="86"><span dir="auto">quality</span></td>
<td valign="center" nowrap="nowrap" width="86"><span dir="auto">78g</span></td>
<td valign="center" nowrap="nowrap" width="86"><span dir="auto">178g</span></td>
<td valign="center" nowrap="nowrap" width="86"><span dir="auto">116g</span></td>
<td valign="center" nowrap="nowrap" width="86"><span dir="auto">268g</span></td>
<td valign="center" nowrap="nowrap" width="86"><span dir="auto">83g</span></td>
</tr>
<tr>
<td valign="center" nowrap="nowrap" width="86"><span dir="auto">illustrate</span></td>
<td valign="center" width="86"><span dir="auto">Suitable for soft needles and small wireless recorders </span><span dir="auto">1 temperature short needle 22mm</span></td>
<td valign="center" width="86"><span dir="auto">Suitable for soft needles and small wireless recorders </span><span dir="auto">1 temperature long needle 150mm</span></td>
<td valign="center" width="86"><span dir="auto">Suitable for soft needle and medium-sized wireless recorder </span><span dir="auto">1 temperature short needle 22mm</span></td>
<td valign="center" width="86"><span dir="auto">Suitable for soft needle and medium-sized wireless recorder </span><span dir="auto">1 temperature long needle 150mm</span></td>
<td valign="center" width="86"><span dir="auto">1 temperature bending pin for wireless logger</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://ieslbd.com/service/freeze-dryer-heat-conduction-block/">Freeze dryer heat conduction block</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/freeze-dryer-heat-conduction-block/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reader Station</title>
		<link>https://ieslbd.com/service/reader-station/</link>
					<comments>https://ieslbd.com/service/reader-station/#respond</comments>
		
		<dc:creator><![CDATA[IESLBD]]></dc:creator>
		<pubDate>Mon, 20 Oct 2025 17:08:39 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12327</guid>

					<description><![CDATA[<p><strong><span dir="auto">Product Overview</span><br />
</strong><span dir="auto">: This is a device used for communication between recorders and computers. Users can operate the temperature verification software on a laptop, download the operation plan to the wireless recorder through the reader, and upload the wireless recorder data after the operation.</span></p>
<p>The post <a href="https://ieslbd.com/service/reader-station/">Reader Station</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="prod_gs" class="prod_gs" data-type="block">
<div class="prod_view_name">
<h1><span id="ShoveWebControl_Text3"><span dir="auto">Reader Station</span></span></h1>
</div>
<div id="prod_view_ms" class="prod_view_ms">
<p><strong><br />
</strong><strong><span dir="auto">Main features</span><br />
</strong><span dir="auto">● 8 slots design</span><br />
<span dir="auto">● </span><span dir="auto">Contact communication with the recorder surface, reliable and durable, easy to operate</span><br />
<span dir="auto">● </span><span dir="auto">Can be expanded and combined with multiple readers, convenient for large-scale recorder operation</span></p>
</div>
</div>
<div class="cle">
<table class="ueditorTableStyle" width="611" cellspacing="0">
<tbody>
<tr class="firstRow">
<td valign="center" nowrap="nowrap" width="23"><strong><span dir="auto">model</span></strong></td>
<td valign="center" nowrap="nowrap" width="22"><strong><span dir="auto">RS8-S Small</span></strong></td>
<td valign="center" nowrap="nowrap" width="23"><strong><span dir="auto">RS8-M Medium</span></strong></td>
<td valign="center" nowrap="nowrap" width="29"><strong><span dir="auto">RS8-MS Hybrid</span></strong></td>
</tr>
<tr>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">Small recorder slot</span></td>
<td valign="center" nowrap="nowrap" width="22"><span dir="auto">8</span></td>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">0</span></td>
<td valign="center" nowrap="nowrap" width="29"><span dir="auto">6</span></td>
</tr>
<tr>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">Medium recorder slot</span></td>
<td valign="center" nowrap="nowrap" width="22"><span dir="auto">0</span></td>
<td valign="center" nowrap="nowrap" width="23">
<span dir="auto">8</span></td>
<td valign="center" nowrap="nowrap" width="29"><span dir="auto">2</span></td>
</tr>
<tr>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">Slot Communication</span></td>
<td colspan="3" valign="center" nowrap="nowrap" width="76"><span dir="auto">2-point contact</span></td>
</tr>
<tr>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">USB port</span></td>
<td colspan="3" valign="center" nowrap="nowrap" width="76"><span dir="auto">1</span></td>
</tr>
<tr>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">Input voltage</span></td>
<td colspan="3" valign="center" nowrap="nowrap" width="76"><span dir="auto">5VDC</span></td>
</tr>
<tr>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">Maximum power consumption</span></td>
<td colspan="3" valign="center" nowrap="nowrap" width="76"><span dir="auto">2W</span></td>
</tr>
<tr>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">Operating temperature</span></td>
<td colspan="3" valign="center" nowrap="nowrap" width="76"><span dir="auto">0°C to 50°C</span></td>
</tr>
<tr>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">Operating humidity</span></td>
<td colspan="3" valign="center" nowrap="nowrap" width="76"><span dir="auto">0%RH to 90%RH</span></td>
</tr>
<tr>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">Protection level</span></td>
<td colspan="3" valign="center" nowrap="nowrap" width="76"><span dir="auto">IP50</span></td>
</tr>
<tr>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">Dimensions (length × width × height)</span></td>
<td colspan="3" valign="center" nowrap="nowrap" width="76"><span dir="auto">161×77.5×26mm</span></td>
</tr>
<tr>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">Shell material</span></td>
<td colspan="3" valign="center" nowrap="nowrap" width="76"><span dir="auto">aluminum alloy</span></td>
</tr>
<tr>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">quality</span></td>
<td valign="center" nowrap="nowrap" width="22"><span dir="auto">256g</span></td>
<td valign="center" nowrap="nowrap" width="23"><span dir="auto">243g</span></td>
<td valign="center" nowrap="nowrap" width="29"><span dir="auto">255g</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://ieslbd.com/service/reader-station/">Reader Station</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/reader-station/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Medium Wireless Data Logger &#8211; Temperature Curved Needle</title>
		<link>https://ieslbd.com/service/medium-wireless-data-logger-temperature-curved-needle/</link>
					<comments>https://ieslbd.com/service/medium-wireless-data-logger-temperature-curved-needle/#respond</comments>
		
		<dc:creator><![CDATA[IESLBD]]></dc:creator>
		<pubDate>Mon, 20 Oct 2025 17:02:34 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12325</guid>

					<description><![CDATA[<p><strong><span dir="auto">Product Overview</span><br />
</strong><span dir="auto">: This is a high- </span><span dir="auto">accuracy</span><span dir="auto"> platinum resistance temperature recorder that is world-class in terms of high temperature resistance, waterproofness, pressure resistance, and low power consumption. It is an accurate, reliable, and trustworthy assistant.</span></p>
<p><strong><span dir="auto">Applicable to</span></strong><br />
<span dir="auto">● Steam sterilizer</span><br />
<span dir="auto">● Water bath sterilizer</span><br />
<span dir="auto">● Freeze dryer</span><br />
<span dir="auto">● Constant temperature and humidity chamber</span><br />
<span dir="auto">● Ultra-low temperature refrigerator</span><br />
<span dir="auto">● Dry heat sterilizer</span><br />
<span dir="auto">● Tunnel oven</span></p>
<p>The post <a href="https://ieslbd.com/service/medium-wireless-data-logger-temperature-curved-needle/">Medium Wireless Data Logger &#8211; Temperature Curved Needle</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="prod_gs" class="prod_gs" data-type="block">
<div class="prod_view_name">
<h1><span id="ShoveWebControl_Text3"><span dir="auto">Medium Wireless Data Logger &#8211; Temperature Curved Needle</span></span></h1>
</div>
<div id="prod_view_ms" class="prod_view_ms">
<p><strong><span dir="auto">Main features</span><br />
</strong><span dir="auto">● 3 million recording times, long battery life, no need to replace batteries for several years</span><br />
<span dir="auto">● </span><span dir="auto">Professionally resistant to high temperature and high pressure water bath harsh environment</span><br />
<span dir="auto">● </span><span dir="auto">High </span><span dir="auto">accuracy</span><span dir="auto"> : ±0.1℃</span><br />
<span dir="auto">● </span><span dir="auto">Measurement range</span><span dir="auto"> : -150℃ </span><span dir="auto">to 400℃</span></p>
<table class="ueditorTableStyle" width="664" cellspacing="0">
<tbody>
<tr class="firstRow">
<td valign="center" width="242"><strong><span dir="auto">model</span></strong></td>
<td valign="center" width="205"><strong><span dir="auto">WL-T1B Universal</span></strong></td>
<td valign="center" width="217"><strong><span dir="auto">WL-T1B-ULT Ultra Low Temperature Type</span></strong></td>
</tr>
<tr>
<td colspan="3" valign="center" width="664"><strong><span dir="auto">Temperature sensor</span></strong></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Number of channels</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">1</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Temperature sensing element</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">PT1000</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Measuring range</span></td>
<td valign="center" width="205"><span dir="auto">-150℃ to 400℃</span></td>
<td valign="center" width="217"><span dir="auto">-150℃ to 400℃</span></td>
</tr>
<tr>
<td colspan="3" valign="center" width="664"><strong><span dir="auto">Accuracy</span></strong></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">        -150℃ to -60℃</span></td>
<td valign="center" width="205"><span dir="auto">NA</span></td>
<td valign="center" width="217"><span dir="auto">±0.1℃</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">        -60℃ to 150℃</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">±0.1℃</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">        150℃ to 400℃</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">±0.15℃</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">resolution</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">0.01℃</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Total length of probe</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">400mm</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Head size (diameter x length)</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">Φ3×20mm</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Tube size (diameter x length)</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">Φ2.5×380mm</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Minimum bending radius of the pipe</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">15mm</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Distance from head to temperature sensing point</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">3mm</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Material</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">316L stainless steel</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Customizable probe length</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">100mm to 400mm</span></td>
</tr>
<tr>
<td colspan="3" valign="center" width="664"><strong><span dir="auto">Recorder</span></strong></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Operating temperature</span></td>
<td valign="center" width="205"><span dir="auto">-60℃ to 150℃</span></td>
<td valign="center" width="217"><span dir="auto">-90℃ to 150℃</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Storage capacity</span></td>
<td colspan="2" valign="center" width="422">
<span dir="auto">32,000 data/channel</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Minimum recording interval</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">1s</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Maximum recording interval</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">999h</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Maximum startup delay</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">999h</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Dimensions (diameter x length)</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">Φ25.8×50mm</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Shell material</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">316L stainless steel, PEEK</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">quality</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">101g</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Pressure</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">0.1kPa to 900kPa ABS</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Protection level</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">Higher than IPX8, resistant to high temperature pressure steam and water bath</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Battery</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">3.6V high temperature battery</span></td>
</tr>
<tr>
<td valign="center" width="242"><span dir="auto">Battery Replacement</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">Research and Engineering</span></td>
</tr>
<tr>
<td rowspan="3" valign="center" width="242"><span dir="auto">Battery life</span></td>
<td colspan="2" valign="center" width="422"><span dir="auto">3 million records/battery, 3 million/200 records verification = 15,000 verifications</span></td>
</tr>
<tr>
<td colspan="2" valign="center" width="422"><span dir="auto">More than 6 years/battery life</span></td>
</tr>
<tr>
<td colspan="2" valign="center" width="422"><span dir="auto">1 year &lt;1%/capacity attenuation</span></td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://ieslbd.com/service/medium-wireless-data-logger-temperature-curved-needle/">Medium Wireless Data Logger &#8211; Temperature Curved Needle</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/medium-wireless-data-logger-temperature-curved-needle/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Medium Wireless Recorder &#8211; Temperature Soft Needle</title>
		<link>https://ieslbd.com/service/medium-wireless-recorder-temperature-soft-needle/</link>
					<comments>https://ieslbd.com/service/medium-wireless-recorder-temperature-soft-needle/#respond</comments>
		
		<dc:creator><![CDATA[IESLBD]]></dc:creator>
		<pubDate>Mon, 20 Oct 2025 16:54:15 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12323</guid>

					<description><![CDATA[<p><strong><span dir="auto">Product Overview</span><br />
</strong><span dir="auto">This is a high- </span><span dir="auto">accuracy</span><span dir="auto"> platinum resistance temperature recorder that is world-class in terms of high temperature resistance, waterproofness, pressure resistance, and low power consumption. It is an accurate, reliable, and trustworthy assistant.</span></p>
<p><strong><span dir="auto">Applicable to</span></strong><br />
<span dir="auto">● Steam sterilizer</span><br />
<span dir="auto">● Water bath sterilizer</span><br />
<span dir="auto">● Freeze dryer</span><br />
<span dir="auto">● Constant temperature and humidity chamber</span><br />
<span dir="auto">● Ultra-low temperature refrigerator</span></p>
<p>The post <a href="https://ieslbd.com/service/medium-wireless-recorder-temperature-soft-needle/">Medium Wireless Recorder &#8211; Temperature Soft Needle</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="prod_gs" class="prod_gs" data-type="block">
<div class="prod_view_name">
<h1><span id="ShoveWebControl_Text3"><span dir="auto">Medium Wireless Recorder &#8211; Temperature Soft Needle</span></span></h1>
</div>
<div id="prod_view_ms" class="prod_view_ms">
<p><strong><span dir="auto">Main features</span><br />
</strong><span dir="auto">● 3 million records, long battery life, no need to replace batteries for years</span><br />
<span dir="auto">● </span><span dir="auto">Professionally resistant to high temperature and high pressure water bath environment</span><br />
<span dir="auto">● </span><span dir="auto">High </span><span dir="auto">accuracy</span><span dir="auto"> : ±0.1℃</span><br />
<span dir="auto">● </span><span dir="auto">Measuring range</span><span dir="auto"> : -200℃ </span><span dir="auto">to 200℃</span></p>
<table class="ueditorTableStyle" width="618" cellspacing="0">
<tbody>
<tr class="firstRow">
<td valign="center" width="33"><strong><span dir="auto">model</span></strong></td>
<td valign="center" width="33"><strong><span dir="auto">WL-T1F General Purpose</span></strong></td>
<td valign="center" width="33"><strong><span dir="auto">WL-T1F-ULT Ultra Low Temperature Type</span></strong></td>
</tr>
<tr>
<td colspan="3" valign="center" width="100"><strong><span dir="auto">Temperature sensor</span></strong></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Number of channels</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">1</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Temperature sensing element</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">PT1000</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Measuring range</span></td>
<td valign="center" width="33"><span dir="auto">-200℃ to 200℃</span></td>
<td valign="center" width="33"><span dir="auto">-200℃ to 200℃</span></td>
</tr>
<tr>
<td colspan="3" valign="center" width="100"><strong><span dir="auto">Accuracy</span></strong></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">        -200℃ to -60℃</span></td>
<td valign="center" width="33"><span dir="auto">NA</span></td>
<td valign="center" width="33"><span dir="auto">±0.1℃</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">        -60℃ to 200℃</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">±0.1℃</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">resolution</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">0.01℃</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Total length of probe</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">1200mm</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Head size (diameter x length)</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">φ2.7x25mm</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Line size (width × height × length)</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">2.3&#215;1.5x1175mm</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Head packaging technology</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">TTP full Teflon protection</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Distance from head to temperature sensing point</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">2mm</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Material</span></td>
<td colspan="2" valign="center" width="66">
<span dir="auto">Teflon</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Customizable probe length</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">100mm to 2000mm</span></td>
</tr>
<tr>
<td colspan="3" valign="center" width="100"><strong><span dir="auto">Recorder</span></strong></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Operating temperature</span></td>
<td valign="center" width="33"><span dir="auto">-60°C to 150°C</span></td>
<td valign="center" width="33"><span dir="auto">-90°C to 150°C</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Storage capacity</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">32,000 data/channel</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Minimum recording interval</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">1s</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Maximum recording interval</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">999h</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Maximum startup delay</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">999h</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Dimensions (diameter x length)</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">Φ20/Φ25.8×106mm</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Shell material</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">316L stainless steel, PEEK</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">quality</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">169g</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Pressure</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">0.1kPa to 900kPa ABS</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Protection level</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">Higher than IPX8, resistant to high temperature pressure steam and water bath</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Battery</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">3.6V high temperature battery</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Battery Replacement</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">Research and Engineering</span></td>
</tr>
<tr>
<td rowspan="3" valign="center" width="33"><span dir="auto">Battery life</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">3 million records/battery, 3 million/200 records verification = 15,000 verifications</span></td>
</tr>
<tr>
<td colspan="2" valign="center" width="66"><span dir="auto">More than 6 years/battery life</span></td>
</tr>
<tr>
<td colspan="2" valign="center" width="66"><span dir="auto">1 year &lt;1%/capacity attenuation</span></td>
</tr>
</tbody>
</table>
</div>
</div>
<p>The post <a href="https://ieslbd.com/service/medium-wireless-recorder-temperature-soft-needle/">Medium Wireless Recorder &#8211; Temperature Soft Needle</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/medium-wireless-recorder-temperature-soft-needle/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Medium Wireless Data Logger &#8211; Temperature Long Needle</title>
		<link>https://ieslbd.com/service/medium-wireless-data-logger-temperature-long-needle/</link>
					<comments>https://ieslbd.com/service/medium-wireless-data-logger-temperature-long-needle/#respond</comments>
		
		<dc:creator><![CDATA[IESLBD]]></dc:creator>
		<pubDate>Mon, 20 Oct 2025 16:50:20 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12321</guid>

					<description><![CDATA[<p><strong><span dir="auto">Product Overview</span></strong><span dir="auto"> : This is a high- accuracy platinum resistance temperature recorder that is world-class in terms of high temperature resistance, waterproofness, pressure resistance, and low power consumption. It is a precise, reliable, and trustworthy assistant.</span></p>
<p><span dir="auto"><strong>Applications</strong> :</span></p>
<ul>
<li><span dir="auto">Steam sterilizers</span></li>
<li><span dir="auto">Water bath sterilizers</span></li>
<li><span dir="auto">Freeze dryers</span></li>
<li><span dir="auto">Constant temperature and humidity chambers</span></li>
<li><span dir="auto">Ultra-low temperature refrigerators.</span><strong><br />
</strong></li>
</ul>
<p>The post <a href="https://ieslbd.com/service/medium-wireless-data-logger-temperature-long-needle/">Medium Wireless Data Logger &#8211; Temperature Long Needle</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="prod_view_name">
<h1><span id="ShoveWebControl_Text3"><span dir="auto">Medium Wireless Data Logger &#8211; Temperature Long Needle</span></span></h1>
</div>
<div id="prod_view_ms" class="prod_view_ms">
<p><span dir="auto">Recommended options for water bath sterilizer validation</span></p>
<p><strong><span dir="auto">Main features</span><br />
</strong><span dir="auto">● 3 million recording times, long battery life, no need to replace batteries for several years</span><br />
<span dir="auto">● </span><span dir="auto">Professionally resistant to high temperature and high pressure water bath harsh environment</span><br />
<span dir="auto">● </span><span dir="auto">High </span><span dir="auto">accuracy</span><span dir="auto"> : ±0.1℃</span></p>
<table class="ueditorTableStyle" width="618" cellspacing="0">
<tbody>
<tr class="firstRow">
<td valign="center" width="33"><strong><span dir="auto">model</span></strong></td>
<td valign="center" width="32"><strong><span dir="auto">WL-T1L Universal</span></strong></td>
<td valign="center" width="33"><strong><span dir="auto">WL-T1L-ULT Ultra Low Temperature Type</span></strong></td>
</tr>
<tr>
<td colspan="3" valign="center" width="100"><strong><span dir="auto">Temperature sensor</span></strong></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Number of channels</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">1</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Temperature sensing element</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">PT1000</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Measuring range</span></td>
<td valign="center" width="32"><span dir="auto">-60℃ to 150℃</span></td>
<td valign="center" width="33"><span dir="auto">-90℃ to 150℃</span></td>
</tr>
<tr>
<td colspan="3" valign="center" width="100"><strong><span dir="auto">Accuracy</span></strong></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">        -90℃ to -60℃</span></td>
<td valign="center" width="32"><span dir="auto">NA</span></td>
<td valign="center" width="33"><span dir="auto">±0.1℃</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">        -60℃ to 150℃</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">±0.1℃</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">resolution</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">0.01℃</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Dimensions (diameter x length)</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">Φ2.7/Φ4×150 mm</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Distance from head to temperature sensing point</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">3mm</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Material</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">316L stainless steel</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Customizable probe length</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">50mm to 300mm</span></td>
</tr>
<tr>
<td colspan="3" valign="center" width="100"><strong><span dir="auto">Recorder</span></strong></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Operating temperature</span></td>
<td valign="center" width="32"><span dir="auto">-60℃ to 150℃</span></td>
<td valign="center" width="33"><span dir="auto">-90℃ to 150℃</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Storage capacity</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">32,000 data/channel</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Minimum recording interval</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">1s</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Maximum recording interval</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">999h</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Maximum startup delay</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">999h</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Dimensions (diameter x length)</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">Φ25.8×50mm</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Shell material</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">316L stainless steel, PEEK</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">quality</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">141g</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Pressure</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">0.1kPa to 900kPa ABS</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Protection level</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">Higher than IPX8, resistant to high temperature pressure steam and water bath</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Battery</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">3.6V high temperature battery</span></td>
</tr>
<tr>
<td valign="center" width="33"><span dir="auto">Battery Replacement</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">Research and Engineering</span></td>
</tr>
<tr>
<td rowspan="3" valign="center" width="33"><span dir="auto">Battery life</span></td>
<td colspan="2" valign="center" width="66"><span dir="auto">3 million records/battery, 3 million/200 records verification = 15,000 verifications</span></td>
</tr>
<tr>
<td colspan="2" valign="center" width="66"><span dir="auto">More than 6 years/battery life</span></td>
</tr>
<tr>
<td colspan="2" valign="center" width="66"><span dir="auto">1 year &lt;1%/capacity attenuation</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://ieslbd.com/service/medium-wireless-data-logger-temperature-long-needle/">Medium Wireless Data Logger &#8211; Temperature Long Needle</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/medium-wireless-data-logger-temperature-long-needle/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Small Wireless Recorder-Pressure</title>
		<link>https://ieslbd.com/service/small-wireless-recorder-pressure/</link>
					<comments>https://ieslbd.com/service/small-wireless-recorder-pressure/#respond</comments>
		
		<dc:creator><![CDATA[IESLBD]]></dc:creator>
		<pubDate>Mon, 20 Oct 2025 16:45:05 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12319</guid>

					<description><![CDATA[<p><strong><span dir="auto">Product Overview</span></strong></p>
<p><span dir="auto">This compact pressure recorder utilizes the world's most advanced electronic technology and structural design, resulting in improved performance while significantly reducing size. Its world-class performance in high-temperature resistance, waterproofness, pressure resistance, and low power consumption makes it a reliable and accurate assistant.</span></p>
<p>&#160;</p>
<p><strong><span dir="auto">Applicable to</span></strong></p>
<p><span dir="auto">● Steam sterilizer</span></p>
<p><span dir="auto">● Water bath sterilizer</span></p>
<p><span dir="auto">● Freeze dryer</span></p>
<p><span dir="auto">● Constant temperature and humidity chamber</span></p>
<p>The post <a href="https://ieslbd.com/service/small-wireless-recorder-pressure/">Small Wireless Recorder-Pressure</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="prod_view_name">
<h1><span id="ShoveWebControl_Text3"><span dir="auto">Small Wireless Recorder-Pressure</span></span></h1>
</div>
<div id="prod_view_ms" class="prod_view_ms">
<p><strong><span dir="auto">Key Features</span></strong></p>
<p><span dir="auto">● Small size</span></p>
<p><span dir="auto">● 6 million recording times, ultra-long battery life, no need to replace batteries for several years</span></p>
<p><span dir="auto">● Professionally withstand the harsh environment of high temperature and high pressure water bath</span></p>
<table class="ueditorTableStyle" width="618" cellspacing="0">
<tbody>
<tr class="firstRow">
<td valign="center" width="32"><strong><span dir="auto">model</span></strong></td>
<td valign="center" width="67"><strong><span dir="auto">SWL-P1</span></strong></td>
</tr>
<tr>
<td colspan="2" valign="center" width="100"><strong><span dir="auto">pressure sensor</span></strong></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Number of channels</span></td>
<td valign="center" width="67"><span dir="auto">1</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Measuring range</span></td>
<td valign="center" width="67"><span dir="auto">0.1kPa to 500kPa ABS</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Accuracy</span></td>
<td valign="center" width="67"><span dir="auto">±0.25%FS</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">resolution</span></td>
<td valign="center" width="67"><span dir="auto">0.01kPa</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Location</span></td>
<td valign="center" width="67"><span dir="auto">built-in</span></td>
</tr>
<tr>
<td colspan="2" valign="center" width="100"><strong><span dir="auto">Recorder</span></strong></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Operating temperature</span></td>
<td valign="center" width="67"><span dir="auto">-60°C to 150°C</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Storage capacity</span></td>
<td valign="center" width="67"><span dir="auto">32,000 data/channel</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Minimum recording interval</span></td>
<td valign="center" width="67"><span dir="auto">1s</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Maximum recording interval</span></td>
<td valign="center" width="67"><span dir="auto">999h</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Maximum startup delay</span></td>
<td valign="center" width="67"><span dir="auto">999h</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Dimensions (diameter x length)</span></td>
<td valign="center" width="67"><span dir="auto">Φ20×50mm</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Shell material</span></td>
<td valign="center" width="67"><span dir="auto">316L stainless steel, PEEK</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">quality</span></td>
<td valign="center" width="67"><span dir="auto">54g</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Pressure</span></td>
<td valign="center" width="67"><strong><br />
</strong><span dir="auto">0.1kPa to 500kPa ABS</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Protection level</span></td>
<td valign="center" width="67"><span dir="auto">Higher than IPX8, resistant to high temperature pressure steam and water bath</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Battery</span></td>
<td valign="center" width="67"><span dir="auto">3.6V high temperature battery</span></td>
</tr>
<tr>
<td valign="center" width="32"><span dir="auto">Battery Replacement</span></td>
<td valign="center" width="67"><span dir="auto">Research and Engineering</span></td>
</tr>
<tr>
<td rowspan="3" valign="center" width="32"><span dir="auto">Battery life</span></td>
<td valign="center" width="67"><span dir="auto">3 million records/battery, 3 million/400 records verification = 7500 verifications</span></td>
</tr>
<tr>
<td valign="center" width="67"><span dir="auto">More than 6 years/battery life</span></td>
</tr>
<tr>
<td valign="center" width="67"><span dir="auto">1 year &lt;1%/capacity attenuation</span></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://ieslbd.com/service/small-wireless-recorder-pressure/">Small Wireless Recorder-Pressure</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/small-wireless-recorder-pressure/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Medium-sized wireless recorder &#8211; temperature and pressure integrated</title>
		<link>https://ieslbd.com/service/medium-sized-wireless-recorder-temperature-and-pressure-integrated/</link>
					<comments>https://ieslbd.com/service/medium-sized-wireless-recorder-temperature-and-pressure-integrated/#respond</comments>
		
		<dc:creator><![CDATA[IESLBD]]></dc:creator>
		<pubDate>Mon, 20 Oct 2025 16:41:14 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12317</guid>

					<description><![CDATA[<p><strong><span dir="auto">Product Overview</span></strong></p>
<p><span dir="auto">It is a high- </span><span dir="auto">accuracy</span><span dir="auto"> platinum resistance temperature and pressure integrated recorder. It is at the world's first-class level in terms of high temperature resistance, waterproofness, pressure resistance and low power consumption. It is an accurate, reliable and trustworthy assistant.</span></p>
<p><strong><span dir="auto">Applicable to</span></strong><br />
<span dir="auto">● Steam sterilizer</span><br />
<span dir="auto">● Water bath sterilizer</span><br />
<span dir="auto">● Freeze dryer</span><br />
<span dir="auto">● Constant temperature and humidity chamber</span></p>
<p>The post <a href="https://ieslbd.com/service/medium-sized-wireless-recorder-temperature-and-pressure-integrated/">Medium-sized wireless recorder &#8211; temperature and pressure integrated</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="prod_view_name">
<h1><span id="ShoveWebControl_Text3"><span dir="auto">Medium-sized wireless recorder &#8211; temperature and pressure integrated</span></span></h1>
</div>
<div id="prod_view_ms" class="prod_view_ms">
<p><strong><span dir="auto">Key Features</span></strong><strong><br />
</strong><span dir="auto">● 3 million record times, ultra-long battery life, no need to replace batteries for years</span><br />
<span dir="auto">● </span><span dir="auto">Professionally resistant to harsh environments of high temperature and high pressure water baths</span><br />
<span dir="auto">● </span><span dir="auto">High temperature </span><span dir="auto">accuracy</span><span dir="auto"> : ±0.05℃</span><br />
<span dir="auto">● </span><span dir="auto">High pressure </span><span dir="auto">accuracy</span><span dir="auto"> : ±0.25%FS (1kPa/10mbar)</span></p>
<table class="ueditorTableStyle" width="618" cellspacing="0">
<tbody>
<tr class="firstRow">
<td valign="center" width="40"><strong><span dir="auto">model</span></strong></td>
<td valign="center" width="67"><strong><span dir="auto">WL-T1P1 Universal</span></strong></td>
</tr>
<tr>
<td colspan="2" valign="center" width="40"><strong><span dir="auto">Temperature sensor</span></strong></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Number of channels</span></td>
<td valign="center" width="67"><span dir="auto">1</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Temperature sensing element</span></td>
<td valign="center" width="67"><span dir="auto">PT1000</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Measuring range</span></td>
<td valign="center" width="67"><span dir="auto">-60℃ to 150℃</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Accuracy</span></td>
<td valign="center" width="67"><span dir="auto">±0.05℃</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">resolution</span></td>
<td valign="center" width="67"><span dir="auto">0.01℃</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Dimensions (diameter x length)</span></td>
<td valign="center" width="67"><span dir="auto">Φ2.5×16mm</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Distance from head to temperature sensing point</span></td>
<td valign="center" width="67"><span dir="auto">3mm</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Material</span></td>
<td valign="center" width="67"><span dir="auto">316L stainless steel</span></td>
</tr>
<tr>
<td colspan="2" valign="center" width="40"><strong><span dir="auto">pressure sensor</span></strong></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Number of channels</span></td>
<td valign="center" width="67"><span dir="auto">1</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Measuring range</span></td>
<td valign="center" width="67"><span dir="auto">0.1kPa to 500kPa ABS</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Accuracy</span></td>
<td valign="center" width="67"><span dir="auto">±0.25%FS (1kPa/10mbar)</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">resolution</span></td>
<td valign="center" width="67"><span dir="auto">0.01kPa</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Location</span></td>
<td valign="center" width="67"><span dir="auto">built-in</span></td>
</tr>
<tr>
<td colspan="2" valign="center" width="40"><strong><span dir="auto">Recorder</span></strong></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Operating temperature</span></td>
<td valign="center" width="67"><span dir="auto">-60°C to 150°C</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Storage capacity</span></td>
<td valign="center" width="67"><span dir="auto">16,000 data/channel</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Minimum recording interval</span></td>
<td valign="center" width="67"><span dir="auto">1s</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Maximum recording interval</span></td>
<td valign="center" width="67"><span dir="auto">999h</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Maximum startup delay</span></td>
<td valign="center" width="67"><span dir="auto">999h</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Dimensions (diameter x length)</span></td>
<td valign="center" width="67"><span dir="auto">Φ25.8×108mm</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Shell material</span></td>
<td valign="center" width="67"><span dir="auto">316L stainless steel, PEEK</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">quality</span></td>
<td valign="center" width="67"><span dir="auto">162g</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Pressure</span></td>
<td valign="center" width="67"><span dir="auto">0.1kPa to 500kPa ABS</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Protection level</span></td>
<td valign="center" width="67"><span dir="auto">Higher than IPX8, resistant to high temperature pressure steam and water bath</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Battery</span></td>
<td valign="center" width="67"><span dir="auto">3.6V high temperature battery</span></td>
</tr>
<tr>
<td valign="center" width="40"><span dir="auto">Battery Replacement</span></td>
<td valign="center" width="67"><span dir="auto">Research and Engineering</span></td>
</tr>
<tr>
<td rowspan="3" valign="center" width="40"><span dir="auto">Battery life</span></td>
<td valign="center" width="67"><span dir="auto">3 million records/battery, 3 million/400 records verification = 7500 verifications</span></td>
</tr>
<tr>
<td valign="center" width="67"><span dir="auto">More than 6 years/battery life</span></td>
</tr>
<tr>
<td valign="center" width="67"><span dir="auto">1 year &lt;1%/capacity attenuation</span></td>
</tr>
</tbody>
</table>
</div>