<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Temperature Calibrator Archives | Instrumentation Engineering Services Ltd.</title>
	<atom:link href="https://ieslbd.com/service-area/temperature-calibrator/feed/" rel="self" type="application/rss+xml" />
	<link>https://ieslbd.com/service-area/temperature-calibrator/</link>
	<description>Accredited calibration laboratory, accredited inspection body and instrument supplier</description>
	<lastBuildDate>Mon, 20 Oct 2025 18:41:18 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://ieslbd.com/wp-content/uploads/2021/04/icon-150x150.png</url>
	<title>Temperature Calibrator Archives | Instrumentation Engineering Services Ltd.</title>
	<link>https://ieslbd.com/service-area/temperature-calibrator/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Temperature Verification Software Power 3000</title>
		<link>https://ieslbd.com/service/temperature-verification-software-power-3000/</link>
					<comments>https://ieslbd.com/service/temperature-verification-software-power-3000/#respond</comments>
		
		<dc:creator><![CDATA[IESLBD]]></dc:creator>
		<pubDate>Mon, 20 Oct 2025 18:40:34 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12362</guid>

					<description><![CDATA[<p>calibration, verify, Report, Compliance and Security</p>
<p>The post <a href="https://ieslbd.com/service/temperature-verification-software-power-3000/">Temperature Verification Software Power 3000</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong><span dir="auto">Temperature Verification Software Power 3000</span></strong></p>
<p>&nbsp;</p>
<p><strong><span dir="auto">calibration</span></strong></p>
<p><span dir="auto">● Multi-point calibration, single-point or multi-point calibration can be achieved</span></p>
<p><span dir="auto">● Various wired calibration modes, including manual or manual + automatic mixed calibration</span></p>
<p><span dir="auto">● In the fully automatic calibration mode, it can automatically communicate with the probe or dry well to automatically complete the calibration</span></p>
<p><span dir="auto">● Support multi-stage compensation and calibration of wireless recorders</span></p>
<p><span dir="auto">● With post-verification function</span></p>
<p><strong><span dir="auto">verify</span></strong></p>
<p>&nbsp;</p>
<p><span dir="auto">● Supports three types of verification: temperature, humidity, and pressure. The verification channel can be expanded infinitely</span></p>
<p><span dir="auto">● Support wired, wireless, and hybrid (wired + wireless) authentication methods</span></p>
<p><span dir="auto">● Support multiple verification start and stop methods</span></p>
<p><span dir="auto">● Can run verification on multiple devices in real time, with no limit on the number of verifications</span></p>
<p><span dir="auto">● Wired verification can observe verification data in real time: trend chart, kill rate calculation, temperature statistics calculation, etc.</span></p>
<p><span dir="auto">● During wireless verification, you can close the software after running it in the background</span></p>
<p><strong><span dir="auto">Report</span></strong></p>
<p>&nbsp;</p>
<p><span dir="auto">● Both calibration and verification can generate original unchangeable calibration data and verification data</span></p>
<p><span dir="auto">● Calibration data can be split into multiple reports as needed</span></p>
<p><span dir="auto">● Verification data can be divided into multiple cycles and multiple stages</span></p>
<p><span dir="auto">● Report content can be flexibly filtered to display important information</span></p>
<p><span dir="auto">● Different parameters can be set to calculate F0 value, FH value, A0 value, etc.</span></p>
<p><span dir="auto">● Calculate cold spots, hot spots, uniformity, fluctuation, etc.</span></p>
<p><span dir="auto">● The verification report calculation content is comprehensive and rich, meeting different calculation needs</span></p>
<p><span dir="auto">● Calibration or verification data can be backed up and restored separately</span></p>
<p><span dir="auto">● Can output files in different formats such as PDF, CSV, Excel, etc.</span></p>
<p><span dir="auto">● Detailed report filtering capabilities</span></p>
<p><strong><span dir="auto">Compliance and Security</span></strong></p>
<p>&nbsp;</p>
<p><span dir="auto">● Comply with FDA 21CFR Part 11 requirements for electronic records, audit trails and electronic signatures</span></p>
<p><span dir="auto">● Comply with EU EN554:1994 on the validation and routine control requirements of moist heat sterilization of medical devices</span></p>
<p><span dir="auto">● Level 3 user management authority</span></p>
<p><span dir="auto">● Audit trail, detailed log tracking records can be used to check every step of the user&#8217;s actions</span></p>
<p><span dir="auto">● Detailed log filtering function, convenient for viewing operation records</span></p>
<p><span dir="auto">● Safely back up data offsite</span></p>
<p>The post <a href="https://ieslbd.com/service/temperature-verification-software-power-3000/">Temperature Verification Software Power 3000</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/temperature-verification-software-power-3000/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Precision platinum resistance thermometer M1P1</title>
		<link>https://ieslbd.com/service/precision-platinum-resistance-thermometer-m1p1/</link>
					<comments>https://ieslbd.com/service/precision-platinum-resistance-thermometer-m1p1/#respond</comments>
		
		<dc:creator><![CDATA[IESLBD]]></dc:creator>
		<pubDate>Mon, 20 Oct 2025 12:19:00 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12302</guid>

					<description><![CDATA[<p><strong><span dir="auto">Product Overview</span></strong></p>
<p><span dir="auto">The precision platinum resistance thermometer is a high-performance handheld precision temperature measuring instrument that can be used as a temperature measurement standard. Its technical indicators are close to those of second-class standard platinum resistance thermometers. It can be used as an external standard with a dry well or liquid bath for various precision temperature measurements.</span></p>
<p>The post <a href="https://ieslbd.com/service/precision-platinum-resistance-thermometer-m1p1/">Precision platinum resistance thermometer M1P1</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="prod_view_name">
<h1><span id="ShoveWebControl_Text3"><span dir="auto">Precision platinum resistance thermometer M1P1</span></span></h1>
</div>
<div id="prod_view_ms" class="prod_view_ms">
<p><strong><span dir="auto">Main features</span></strong><span dir="auto"> : </span><strong><br />
</strong><span dir="auto">All technical indicators are close to those of second-class standard platinum resistance thermometers</span></p>
<p><span dir="auto">● System accuracy: ±0.025°C</span></p>
<p><span dir="auto">●   </span><span dir="auto">High resolution, full range: 0.001C</span></p>
<p><span dir="auto">● Full touch screen operation</span></p>
<p><span dir="auto">The  </span><span dir="auto"> metal protection tube can ensure that the probe will not be contaminated when used in a cheap metal environment</span></p>
</div>
<p>&nbsp;</p>
<table class="ueditorTableStyle" width="618" cellspacing="0">
<tbody>
<tr class="firstRow">
<td valign="top" width="44"><strong><span dir="auto">model</span></strong></td>
<td valign="top" width="55"><strong><span dir="auto">M1P1</span></strong></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Measuring range</span></td>
<td valign="top" width="55"> <span dir="auto">-200℃ to 500℃</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Accuracy</span></td>
<td valign="top" width="55"><span dir="auto">±0.025°C</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Short-term stability</span></td>
<td valign="top" width="55"><span dir="auto">±0.01℃/24 hours (daily drift does not exceed ±0.01℃)</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">resolution</span></td>
<td valign="top" width="55"><span dir="auto">0.001℃</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Temperature coefficient</span></td>
<td valign="top" width="55"><span dir="auto">α=0.00385</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Wire system</span></td>
<td valign="top" width="55"><span dir="auto">4-wire</span></td>
</tr>
<tr>
<td colspan="2" valign="top" width="100"><strong><span dir="auto">Temperature probe</span></strong></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Thermal cycling characteristics</span></td>
<td valign="top" width="55"><span dir="auto">Better than </span><span dir="auto">±0.01°C</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Thermal hysteresis effect</span></td>
<td valign="top" width="55"><span dir="auto">≤0.01°C</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Self-heating effect</span></td>
<td valign="top" width="55"><span dir="auto">Meet the second-class standard platinum resistance thermometer indicators</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Response time</span></td>
<td valign="top" width="55"><span dir="auto">T63=9s</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Head packaging material</span></td>
<td valign="top" width="55"><span dir="auto">High temperature alloy</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Conductor outer material</span></td>
<td valign="top" width="55"><span dir="auto">Teflon</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Wire operating temperature</span></td>
<td valign="top" width="55"><span dir="auto">-60℃ to 180℃</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Head size (diameter </span><span dir="auto">x length)</span></td>
<td valign="top" width="55"><span dir="auto">Φ3.1×300mm</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Wire size (diameter </span><span dir="auto">x length)</span></td>
<td valign="top" width="55"><span dir="auto">Φ3.5×2500mm</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Tail terminal</span></td>
<td valign="top" width="55"><span dir="auto">Anti-drop aviation universal plug</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Origin of temperature sensing element</span></td>
<td valign="top" width="55"><span dir="auto">China</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Notice</span></td>
<td valign="top" width="55"><span dir="auto">Do not vibrate</span></td>
</tr>
<tr>
<td colspan="2" valign="top" width="100"><strong><span dir="auto">thermometer</span></strong></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Anti-drop aviation probe port</span></td>
<td valign="top" width="55"><span dir="auto">1</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Anti-slip aviation universal port</span></td>
<td valign="top" width="55"><span dir="auto">1</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">communication</span></td>
<td valign="top" width="55"><span dir="auto">Can communicate with the research and development verification instrument</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Display size</span></td>
<td valign="top" width="55"><span dir="auto">4.0 inches</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Display resolution</span></td>
<td valign="top" width="55"><span dir="auto">480×800</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">touchscreen</span></td>
<td valign="top" width="55"><span dir="auto">4-wire resistance</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Input voltage</span></td>
<td valign="top" width="55"><span dir="auto">12VDC</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Maximum power consumption</span></td>
<td valign="top" width="55"><span dir="auto">2.4W</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Operating temperature</span></td>
<td valign="top" width="55"><span dir="auto">15℃ to 35℃</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Operating humidity</span></td>
<td valign="top" width="55"><span dir="auto">0%RH to 90%RH</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Protection level</span></td>
<td valign="top" width="55"><span dir="auto">IP50</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Dimensions (width </span><span dir="auto">× height × depth)</span></td>
<td valign="top" width="55"><span dir="auto">76.8×136.2×36.8mm</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Shell material</span></td>
<td valign="top" width="55"><span dir="auto">aluminum alloy</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">quality</span></td>
<td valign="top" width="55"><span dir="auto">421g</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Battery</span></td>
<td valign="top" width="55"><span dir="auto">Rechargeable lithium battery</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Battery disassembly and assembly</span></td>
<td valign="top" width="55"><span dir="auto">Cannot be disassembled</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Battery life</span></td>
<td valign="top" width="55"><span dir="auto">A full charge can work for about </span><span dir="auto">8 hours</span></td>
</tr>
<tr>
<td valign="top" width="44"><span dir="auto">Notice</span></td>
<td valign="top" width="55"><span dir="auto">Do not use in harsh environments</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://ieslbd.com/service/precision-platinum-resistance-thermometer-m1p1/">Precision platinum resistance thermometer M1P1</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>