<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>| Instrumentation Engineering Services Ltd.</title>
	<atom:link href="https://ieslbd.com/shop/feed/" rel="self" type="application/rss+xml" />
	<link>https://ieslbd.com/shop/</link>
	<description>Accredited calibration laboratory, accredited inspection body and instrument supplier</description>
	<lastBuildDate>Thu, 30 Oct 2025 04:31:45 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://ieslbd.com/wp-content/uploads/2021/04/icon-150x150.png</url>
	<title>| Instrumentation Engineering Services Ltd.</title>
	<link>https://ieslbd.com/shop/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ArizonaLIMS</title>
		<link>https://ieslbd.com/service/arizonalims/</link>
					<comments>https://ieslbd.com/service/arizonalims/#respond</comments>
		
		<dc:creator><![CDATA[Md. Yousuf]]></dc:creator>
		<pubDate>Thu, 30 Oct 2025 04:31:45 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12535</guid>

					<description><![CDATA[<p>ArizonaLIMS is a Laboratory Information Management System that helps labs organize and track important data. It improves accuracy, ensures compliance with regulations, and makes lab work more efficient. With easy-to-use tools and streamlined workflows, ArizonaLIMS supports teamwork, speeds up processes, and helps scientists make better data-driven decisions.</p>
<p>The post <a href="https://ieslbd.com/service/arizonalims/">ArizonaLIMS</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>ArizonaLIMS is a Laboratory Information Management System that helps labs organize and track important data. It improves accuracy, ensures compliance with regulations, and makes lab work more efficient. With easy-to-use tools and streamlined workflows, ArizonaLIMS supports teamwork, speeds up processes, and helps scientists make better data-driven decisions.</p>
<p>The post <a href="https://ieslbd.com/service/arizonalims/">ArizonaLIMS</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/arizonalims/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Type K 72″/180″ Glass Braided Thermocouple (4 Pack)</title>
		<link>https://ieslbd.com/service/type-k-72%e2%80%b3-180%e2%80%b3-glass-braided-thermocouple-4-pack/</link>
					<comments>https://ieslbd.com/service/type-k-72%e2%80%b3-180%e2%80%b3-glass-braided-thermocouple-4-pack/#respond</comments>
		
		<dc:creator><![CDATA[Md. Yousuf]]></dc:creator>
		<pubDate>Tue, 28 Oct 2025 12:55:59 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12530</guid>

					<description><![CDATA[<p>This 4-pack of Type K glass braided thermocouples (72″/180″) provides durable, high-temperature measurement solutions for industrial and laboratory applications.</p>
<p>The post <a href="https://ieslbd.com/service/type-k-72%e2%80%b3-180%e2%80%b3-glass-braided-thermocouple-4-pack/">Type K 72″/180″ Glass Braided Thermocouple (4 Pack)</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>24 AWG glass braided Type K thermocouple (4 pack) with SMP plug. Available in 72 in. or 180 in. length. The wire is rated from temperatures -100°C to 482°C (-148°F to 900°F).</p>
<table id="tablepress-24-awg-glass-braided-thermocouple-5-pack-general" class="tablepress tablepress-id-24-awg-glass-braided-thermocouple-5-pack-general">
<tbody>
<tr class="row-1">
<td class="column-1">Probe Type</td>
<td class="column-2">Type K, Thermocouple</td>
</tr>
<tr class="row-2">
<td class="column-1">Temperature Range</td>
<td class="column-2">-100°C to 482°C (-148°F to 900°F)</td>
</tr>
<tr class="row-3">
<td class="column-1">Accuracy</td>
<td class="column-2">±1.1 °C</td>
</tr>
<tr class="row-4">
<td class="column-1">Resolution</td>
<td class="column-2">0.1 °C</td>
</tr>
<tr class="row-5">
<td class="column-1">Lead Wire Material</td>
<td class="column-2">Glass Braided Insulation</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://ieslbd.com/service/type-k-72%e2%80%b3-180%e2%80%b3-glass-braided-thermocouple-4-pack/">Type K 72″/180″ Glass Braided Thermocouple (4 Pack)</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/type-k-72%e2%80%b3-180%e2%80%b3-glass-braided-thermocouple-4-pack/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Thermocouple Probe Assembly for Glycol Bottle</title>
		<link>https://ieslbd.com/service/thermocouple-probe-assembly-for-glycol-bottle/</link>
					<comments>https://ieslbd.com/service/thermocouple-probe-assembly-for-glycol-bottle/#respond</comments>
		
		<dc:creator><![CDATA[Md. Yousuf]]></dc:creator>
		<pubDate>Tue, 28 Oct 2025 12:41:56 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12529</guid>

					<description><![CDATA[<p>The Thermocouple Probe Assembly for Glycol Bottle delivers precise temperature measurements when used with glycol-filled monitoring bottles, ensuring accurate cold chain tracking.</p>
<p>The post <a href="https://ieslbd.com/service/thermocouple-probe-assembly-for-glycol-bottle/">Thermocouple Probe Assembly for Glycol Bottle</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Thermocouple Probe Assembly for 30ml, 60ml and 250ml Glycol Bottles.</p>
<h3>General</h3>
<table id="tablepress-thermocouple-probe-assembly-for-glycol-bottle-general-no-3" class="tablepress tablepress-id-thermocouple-probe-assembly-for-glycol-bottle-general">
<tbody>
<tr class="row-1">
<td class="column-1">Probe Type</td>
<td class="column-2">Type K, Thermocouple</td>
</tr>
<tr class="row-2">
<td class="column-1">Temperature Range<br />
(Glycol Bottle Dependant)</td>
<td class="column-2">-50 °C to +80 °C (-58 °F to +176 °F)</td>
</tr>
<tr class="row-3">
<td class="column-1">Accuracy</td>
<td class="column-2">±1.1 °C</td>
</tr>
<tr class="row-4">
<td class="column-1">Resolution</td>
<td class="column-2">0.1 °C</td>
</tr>
<tr class="row-5">
<td class="column-1">Sheath Material</td>
<td class="column-2">Stainless Steel Sheath</td>
</tr>
<tr class="row-6">
<td class="column-1">Sheath Length</td>
<td class="column-2">2.5 inches, 3 inches or 4.5 inches</td>
</tr>
<tr class="row-7">
<td class="column-1">Sheath Temperature Range</td>
<td class="column-2">232 °C (450 °F)</td>
</tr>
<tr class="row-8">
<td class="column-1">Lead Wire Material</td>
<td class="column-2">PFA-Insulated Wire</td>
</tr>
<tr class="row-9">
<td class="column-1">Lead Wire Temperature Range</td>
<td class="column-2">260 °C (500 °F)</td>
</tr>
<tr class="row-10">
<td class="column-1">Cable Length</td>
<td class="column-2">72 inches</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://ieslbd.com/service/thermocouple-probe-assembly-for-glycol-bottle/">Thermocouple Probe Assembly for Glycol Bottle</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/thermocouple-probe-assembly-for-glycol-bottle/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Glycol Bottle with Thermocouple Probe Assembly</title>
		<link>https://ieslbd.com/service/glycol-bottle-with-thermocouple-probe-assembly/</link>
					<comments>https://ieslbd.com/service/glycol-bottle-with-thermocouple-probe-assembly/#respond</comments>
		
		<dc:creator><![CDATA[Md. Yousuf]]></dc:creator>
		<pubDate>Tue, 28 Oct 2025 12:38:05 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12527</guid>

					<description><![CDATA[<p>The Glycol Bottle with Thermocouple Probe Assembly provides stabilized temperature readings by simulating product conditions, ideal for vaccine storage and refrigerator monitoring.</p>
<p>The post <a href="https://ieslbd.com/service/glycol-bottle-with-thermocouple-probe-assembly/">Glycol Bottle with Thermocouple Probe Assembly</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>0ml, 60ml and 250ml Glycol Bottles with Thermocouple Probe Assembly</p>
<h2>Specifications</h2>
<h3>General</h3>
<table id="tablepress-glycol-bottle-with-thermocouple-probe-assembly-general-no-3" class="tablepress tablepress-id-glycol-bottle-with-thermocouple-probe-assembly-general">
<tbody>
<tr class="row-1">
<td class="column-1">Probe Type</td>
<td class="column-2">Type K, Thermocouple</td>
</tr>
<tr class="row-2">
<td class="column-1">Temperature Range<br />
(Glycol Bottle Dependant)</td>
<td class="column-2">-50 °C to +80 °C (-58 °F to +176 °F)</td>
</tr>
<tr class="row-3">
<td class="column-1">Accuracy</td>
<td class="column-2">±1.1 °C</td>
</tr>
<tr class="row-4">
<td class="column-1">Resolution</td>
<td class="column-2">0.1 °C</td>
</tr>
<tr class="row-5">
<td class="column-1">Sheath Material</td>
<td class="column-2">Stainless Steel Sheath</td>
</tr>
<tr class="row-6">
<td class="column-1">Sheath Length</td>
<td class="column-2">2.5 inches, 3 inches or 4.5 inches</td>
</tr>
<tr class="row-7">
<td class="column-1">Sheath Temperature Range</td>
<td class="column-2">232 °C (450 °F)</td>
</tr>
<tr class="row-8">
<td class="column-1">Lead Wire Material</td>
<td class="column-2">PFA-Insulated Wire</td>
</tr>
<tr class="row-9">
<td class="column-1">Lead Wire Temperature Range</td>
<td class="column-2">260 °C (500 °F)</td>
</tr>
<tr class="row-10">
<td class="column-1">Cable Length</td>
<td class="column-2">72 inches</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://ieslbd.com/service/glycol-bottle-with-thermocouple-probe-assembly/">Glycol Bottle with Thermocouple Probe Assembly</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/glycol-bottle-with-thermocouple-probe-assembly/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>PRHTemp101A</title>
		<link>https://ieslbd.com/service/prhtemp101a/</link>
					<comments>https://ieslbd.com/service/prhtemp101a/#respond</comments>
		
		<dc:creator><![CDATA[Md. Yousuf]]></dc:creator>
		<pubDate>Tue, 28 Oct 2025 12:29:03 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12524</guid>

					<description><![CDATA[<p>The PRHTemp101A is a compact pressure, humidity, and temperature data logger designed for precise, reliable environmental monitoring in industrial and laboratory settings.</p>
<p>The post <a href="https://ieslbd.com/service/prhtemp101a/">PRHTemp101A</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The PRHTemp101A is a compact, pressure, humidity and temperature data logger. Includes standard calibration certificate.</p>
<p>Key Features:</p>
<ul>
<li>Compact Size</li>
<li>Configurable Alarms</li>
<li>Memory Capacity of 500,000+ Readings</li>
</ul>
<p>The PRHTemp101A is a pressure, humidity, and temperature data logger. Its compact design and 10-year battery life make it ideal for long-term deployment.</p>
<p>The PRHTemp101A has multiple start/stop functions and can even be programmed to start recording 18 months in advance. It also features user-specified high/low alarm limits (pressure channel only) and the ability to store up to 523,776 readings.</p>
<p>The PRHTemp101A is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.</p>
<h2>Specifications</h2>
<div id="" class="specs-table-wrapper">
<h3>General</h3>
<table id="tablepress-prhtemp101a-general-no-3" class="tablepress tablepress-id-prhtemp101a-general">
<tbody>
<tr class="row-1">
<td class="column-1">Memory</td>
<td class="column-2">523,776 readings</td>
</tr>
<tr class="row-2">
<td class="column-1">Reading Rate</td>
<td class="column-2">1 reading every second up to 1 reading every 24 hours</td>
</tr>
<tr class="row-3">
<td class="column-1">Baud Rate</td>
<td class="column-2">115,200</td>
</tr>
<tr class="row-4">
<td class="column-1">LED Indicators</td>
<td class="column-2">Red &amp; Green</td>
</tr>
<tr class="row-5">
<td class="column-1">Battery Life</td>
<td class="column-2">10 years typical (at a 15 minute reading rate)</td>
</tr>
<tr class="row-6">
<td class="column-1">Material</td>
<td class="column-2">Polycarbonate</td>
</tr>
<tr class="row-7">
<td class="column-1">Dimensions</td>
<td class="column-2">1.4 in x 2.1 in x 0.6 in (35 mm x 54 mm x 15 mm)</td>
</tr>
<tr class="row-8">
<td class="column-1">Operating Environment</td>
<td class="column-2">-40 °C to +80 °C (-40 °F to +176 °F), 0 %RH to 95 %RH non-condensing, 0.002 PSIA to 100 PSIA</td>
</tr>
<tr class="row-9">
<td class="column-1">Required Interface Package</td>
<td class="column-2">IFC200</td>
</tr>
<tr class="row-10">
<td class="column-1">Approvals</td>
<td class="column-2">CE</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<div id="" class="specs-table-wrapper">
<h3>Temperature</h3>
<table id="tablepress-prhtemp101a-temperature-no-2" class="tablepress tablepress-id-prhtemp101a-temperature">
<tbody>
<tr class="row-1">
<td class="column-1">Internal Channel Temperature Sensor</td>
<td class="column-2">Resistance Temperature Detector (RTD)</td>
</tr>
<tr class="row-2">
<td class="column-1">Internal Channel Temperature Range</td>
<td class="column-2">-40 °C to +80 °C (-40 °F to +176 °F)</td>
</tr>
<tr class="row-3">
<td class="column-1">Internal Channel Temperature Resolution</td>
<td class="column-2">0.01 °C (0.018 °F)</td>
</tr>
<tr class="row-4">
<td class="column-1">Internal Channel Temperature Calibrated Accuracy</td>
<td class="column-2">±0.5 °C (±0.9 °F) from 0 °C to +55 °C (+32 °F to +131 °F)<br />
±1.0 °C (±1.8 °F) from -40 °C to 0 °C (-40 °F to +32 °F)<br />
and +55.01 °C to +80 °C (+131.01 °F to +176 °F)</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<div id="" class="specs-table-wrapper">
<h3>Pressure</h3>
<table id="tablepress-prhtemp101a-pressure-no-2" class="tablepress tablepress-id-prhtemp101a-pressure">
<tbody>
<tr class="row-1">
<td class="column-1">Pressure Sensor</td>
<td class="column-2">Piezoresistive</td>
</tr>
<tr class="row-2">
<td class="column-1">Pressure Range</td>
<td class="column-2">250 mbar to 1300 mbar</td>
</tr>
<tr class="row-3">
<td class="column-1">Pressure Resolution</td>
<td class="column-2">0.02 mbar</td>
</tr>
<tr class="row-4">
<td class="column-1">Pressure Calibrated Accuracy</td>
<td class="column-2">10 mbar (+5 °C to +55 °C / +41 °F to +131 °F)</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://ieslbd.com/service/prhtemp101a/">PRHTemp101A</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/prhtemp101a/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>RFRHTemp2000A</title>
		<link>https://ieslbd.com/service/rfrhtemp2000a-2/</link>
					<comments>https://ieslbd.com/service/rfrhtemp2000a-2/#respond</comments>
		
		<dc:creator><![CDATA[Md. Yousuf]]></dc:creator>
		<pubDate>Tue, 28 Oct 2025 12:25:47 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12522</guid>

					<description><![CDATA[<p>The RFPRHTemp2000A is a wireless temperature, humidity, and pressure data logger offering real-time monitoring, customizable alerts, and cloud connectivity for seamless environmental control.</p>
<p>The post <a href="https://ieslbd.com/service/rfrhtemp2000a-2/">RFRHTemp2000A</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The RFRHTemp2000A is a wireless temperature and humidity data logger. Includes ISO17025-accredited calibration certificate.</p>
<p>Key Features:</p>
<ul>
<li>Digital Display</li>
<li>Continuous Monitoring</li>
<li>Configurable Alarms &amp; Notifications</li>
</ul>
<p>The RFRHTemp2000A is a wireless temperature and humidity data logger. Designed with external humidity and RTD-based temperature sensors, the RFRHTemp2000A provides a fast response time for both parameters.</p>
<p>This device features an LCD screen that provides instant access to current readings, minimum, maximum and average statistics. Equipped with user-programmable alarms, the RFRHTemp2000A will alert or notify users via email or text when thresholds are breached, allowing users to take immediate action.</p>
<p>The RFRHTemp2000A is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.</p>
<p>The RFRHTemp2000A is also MadgeTech Cloud Services ready, providing users the ability to monitor data remotely on any smartphone, tablet or internet-enabled device.</p>
<p><em>Note: RFC wireless interface required.</p>
<p></em></p>
<h2>Specifications</h2>
<div id="" class="specs-table-wrapper">
<h3>General</h3>
<table id="tablepress-rfrhtemp2000a-general-no-3" class="tablepress tablepress-id-rfrhtemp2000a-general">
<tbody>
<tr class="row-1">
<td class="column-1">Memory</td>
<td class="column-2">16,128 readings (all channels enabled)</td>
</tr>
<tr class="row-2">
<td class="column-1">Reading Rate</td>
<td class="column-2">1 reading every second up to 1 reading every 24 hours</td>
</tr>
<tr class="row-3">
<td class="column-1">Baud Rate</td>
<td class="column-2">250,000</td>
</tr>
<tr class="row-4">
<td class="column-1">LED Indicators</td>
<td class="column-2">Green, Blue &amp; Red</td>
</tr>
<tr class="row-5">
<td class="column-1">Battery Life</td>
<td class="column-2">3 years typical at a 1 minute reading rate</td>
</tr>
<tr class="row-6">
<td class="column-1">Material</td>
<td class="column-2">ABS plastic</td>
</tr>
<tr class="row-7">
<td class="column-1">Dimensions</td>
<td class="column-2">3.0 in x 3.5 in x 0.95 in (76.2 mm x 88.9 mm x 24.1 mm) &#8211; Data logger only</td>
</tr>
<tr class="row-8">
<td class="column-1">IP Rating</td>
<td class="column-2">IP22</td>
</tr>
<tr class="row-9">
<td class="column-1">Operating Environment</td>
<td class="column-2">-20 °C to +60 °C (-4 °F to +140 °F) 0 %RH to 95 %RH non-condensing</td>
</tr>
<tr class="row-10">
<td class="column-1">Required Interface Package</td>
<td class="column-2">RFC1000</td>
</tr>
<tr class="row-11">
<td class="column-1">Approvals</td>
<td class="column-2">US (FCC), CA (IC), CE, South Korea (KCC), China (CMIIT), Japan (LCIE)</td>
</tr>
<tr class="row-12">
<td class="column-1">Countries approved for use, purchase and distribution</td>
<td class="column-2">Australia, Austria, Belgium, Bulgaria, Canada, Chile, China, Colombia, Croatia, Cyprus, Czech Republic, Denmark, Ecuador, Estonia, Finland, France, Germany, Greece, Honduras, Hungary, Iceland, Ireland, Israel, Japan, Latvia, Liechtenstein, Lithuania, Luxembourg, Malaysia, Malta, Mexico, New Zealand, Norway, Peru, Poland, Portugal, Romania, Saudi Arabia, Singapore, Slovakia, Slovenia, South Africa, South Korea, Spain, Sweden, Switzerland, Thailand, The Netherlands, Turkey, United Kingdom, United States, Venezuela, Vietnam</td>
</tr>
</tbody>
</table>
</div>
<p><em> </em></p>
<div id="" class="specs-table-wrapper">
<h3>Temperature</h3>
<table id="tablepress-rfrhtemp2000a-temperature-no-2" class="tablepress tablepress-id-rfrhtemp2000a-temperature">
<tbody>
<tr class="row-1">
<td class="column-1">Internal Channel Temperature Sensor</td>
<td class="column-2">Resistance Temperature Detector (RTD)</td>
</tr>
<tr class="row-2">
<td class="column-1">Internal Channel Temperature Range</td>
<td class="column-2">-20 °C to +60 °C (-4 °F to +140 °F)</td>
</tr>
<tr class="row-3">
<td class="column-1">Internal Channel Temperature Resolution</td>
<td class="column-2">0.01 °C (0.018 °F)</td>
</tr>
<tr class="row-4">
<td class="column-1">Internal Channel Temperature Calibrated Accuracy</td>
<td class="column-2">±0.5 °C (0 °C to 55 °C)</td>
</tr>
</tbody>
</table>
</div>
<p><em> </em></p>
<div id="" class="specs-table-wrapper">
<h3>Humidity</h3>
<table id="tablepress-rfrhtemp2000a-humidity-no-2" class="tablepress tablepress-id-rfrhtemp2000a-humidity">
<tbody>
<tr class="row-1">
<td class="column-1">Humidity Sensor</td>
<td class="column-2">Relative Humidity Sensor</td>
</tr>
<tr class="row-2">
<td class="column-1">Humidity Range</td>
<td class="column-2">0 %RH to 95 %RH</td>
</tr>
<tr class="row-3">
<td class="column-1">Humidity Resolution</td>
<td class="column-2">0.1 %RH</td>
</tr>
<tr class="row-4">
<td class="column-1">Humidity Calibrated Accuracy</td>
<td class="column-2">±3.0 %RH</td>
</tr>
<tr class="row-5">
<td class="column-1">Specified Accuracy Range</td>
<td class="column-2">25 %RH to 75 %RH; +20 °C to +40 °C<br />
Hysteresis Error 1 % typical, 3 % Maximum</td>
</tr>
</tbody>
</table>
</div>
<p><em> </em></p>
<div id="" class="specs-table-wrapper">
<h3>Wireless</h3>
<table id="tablepress-rfrhtemp2000a-wireless-no-2" class="tablepress tablepress-id-rfrhtemp2000a-wireless">
<tbody>
<tr class="row-1">
<td class="column-1">RF Carrier Frequency</td>
<td class="column-2">2.45 GHz IEEE 802.15.4 ultra-low power MadgeNET Wireless Transceiver with fully by-directional communication.</td>
</tr>
<tr class="row-2">
<td class="column-1">RF Baud Rate</td>
<td class="column-2">250,000</td>
</tr>
<tr class="row-3">
<td class="column-1">Output Power</td>
<td class="column-2">+0 dBm typical</td>
</tr>
<tr class="row-4">
<td class="column-1">Receiver Sensitivity</td>
<td class="column-2">-95 dBm typical</td>
</tr>
<tr class="row-5">
<td class="column-1">Typical outdoors Line of sight</td>
<td class="column-2">Up to 2,000 ft</td>
</tr>
<tr class="row-6">
<td class="column-1">Typical Indoors line of sight</td>
<td class="column-2">Up to 500 ft</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://ieslbd.com/service/rfrhtemp2000a-2/">RFRHTemp2000A</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/rfrhtemp2000a-2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HiTemp140</title>
		<link>https://ieslbd.com/service/hitemp140/</link>
					<comments>https://ieslbd.com/service/hitemp140/#respond</comments>
		
		<dc:creator><![CDATA[Md. Yousuf]]></dc:creator>
		<pubDate>Tue, 28 Oct 2025 12:16:33 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12487</guid>

					<description><![CDATA[<p>The HiTemp140 is a premier high-temperature data logger uniquely engineered for performance in harsh environmental conditions. This submersible unit is crafted to deliver reliable data logging in industries where temperature accuracy is critical. With its robust stainless steel design, the HiTemp140 is especially suited for applications in pharmaceuticals, food processing, and industrial manufacturing. These sectors demand precise monitoring tools that can withstand not only high temperatures but also the rigorous cleaning processes often required in such settings.</p>
<p>The post <a href="https://ieslbd.com/service/hitemp140/">HiTemp140</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HiTemp140 is a precision high-temperature data logger. Includes ISO17025 accredited calibration certificate.</p>
<p>Key Features:</p>
<ul>
<li>Submersible</li>
<li>Available in Various Probe Lengths &amp; Styles</li>
<li>Measures Temperatures from -40 °C to +140 °CThe HiTemp140 is a premier high-temperature data logger uniquely engineered for performance in harsh environmental conditions. This submersible unit is crafted to deliver reliable data logging in industries where temperature accuracy is critical. With its robust stainless steel design, the HiTemp140 is especially suited for applications in pharmaceuticals, food processing, and industrial manufacturing. These sectors demand precise monitoring tools that can withstand not only high temperatures but also the rigorous cleaning processes often required in such settings.
<p>The HiTemp140 operates within a standard temperature range of -40 °C to +140 °C (-40 °F to +284 °F), making it a robust tool for a variety of high-temperature applications. For processes that reach higher temperatures, the HiTemp140-5.25, HiTemp140-7, <a href="https://www.madgetech.com/products/hitemp140-fp/">HiTemp140-FP</a> and <a href="https://www.madgetech.com/products/hitemp140-pt/">HiTemp140-PT</a> can be used with thermal barriers including the <a href="https://www.madgetech.com/products/hitemp140-ts/">HiTemp140-TS</a>, which can extend the temperature range up to 250 °C (482 °F).</p>
<p>The HiTemp140 is available with a variety of probe lengths and styles, each designed for specific scenarios and applications. The selection of a probe depends on factors such as the nature of the medium being monitored, the required insertion depth, and the environment’s physical space constraints. To learn more about the variety of probes available, please <a href="https://www.madgetech.com/resources/hitemp140-probe-styles/">click here</a>. With a substantial storage capacity for up to 32,256 time and date-stamped readings, the HiTemp140 can continuously record data over extended periods.</p>
<p>Additionally, it is fully compatible with the MadgeTech 4 Data Logger Software, which facilitates straightforward setup, comprehensive data management, and detailed analysis. This software compatibility enhances operational efficiency and ensures precision in data logging tasks, making it an ideal choice for rigorous monitoring needs.</p>
<p><em>Body of data logger cannot exceed 140 °C (284 °F), but can extend to higher temperatures when used with MadgeTech’s thermal barrier options.</em></p>
<p>Specifications:</li>
</ul>
<div id="" class="specs-table-wrapper">
<h3>General</h3>
<table id="tablepress-hitemp140-general-no-3" class="tablepress tablepress-id-hitemp140-general">
<tbody>
<tr class="row-1">
<td class="column-1">Memory</td>
<td class="column-2">32,256 readings</td>
</tr>
<tr class="row-2">
<td class="column-1">Reading Rate</td>
<td class="column-2">1 reading every second up to 1 reading every 24 hours</td>
</tr>
<tr class="row-3">
<td class="column-1">Baud Rate</td>
<td class="column-2">125,000</td>
</tr>
<tr class="row-4">
<td class="column-1">Battery Life</td>
<td class="column-2">2 years typical (1 minute reading rate)</p>
<p>Fast reading intervals and extreme temperatures will shorten the battery life substantially</p>
<p>User Replaceable Battery</td>
</tr>
<tr class="row-5">
<td class="column-1">Material</td>
<td class="column-2">316 Stainless Steel, Radel</td>
</tr>
<tr class="row-6">
<td class="column-1">HiTemp 140 Rigid and Rigid Transitional Diameter Dimensions</td>
<td class="column-2">HiTemp140-1 Body: 1.55 in x 0.97 in dia. (40 mm x 25 mm dia.)<br />
Probe: 1 in x 0.125 in dia. (0.188 in transitional dia.)<br />
25 mm x 3.2 mm dia. (4.8 mm transitional dia.)<br />
Body (for 2 in, 5.25 in, 7 in;): 1.75 in x 0.97 in dia. (45 mm x 25 mm dia.)HiTemp140-2 : 2.0 in x 0.188 in dia. (51 mm x 4.8 mm)</p>
<p>HiTemp140-2-TD: 2.0 in x 0.125 in dia. (0.188 in transitional dia.)<br />
(51 mm x 3.2 mm dia. (4.8 mm transitional dia.)</p>
<p>HiTemp140-5.25: 5.25 in x 0.188 in dia. (134 mm x 4.8 mm)</p>
<p>HiTemp140-5.25-TD: 5.25 in x 0.125 in dia. (0.188 in transitional dia.)<br />
(134 mm x 3.2 mm dia. (4.8 mm transitional dia.)</p>
<p>HiTemp140-7: 7.0 in x 0.188 in dia. (178 mm x 4.8 mm dia.)</td>
</tr>
<tr class="row-7">
<td class="column-1">HiTemp140 Fast Response Probe Dimensions</td>
<td class="column-2">Body: 1.89 in x 0.97 in x 0.97 in (48.1 mm x 24.6 mm x 24.6 mm)<br />
Probe: 1.75 in x 0.0625 in dia. (0.188 in transitional dia.) (44.5 mm x 1.59 mm (4.78 mm Transitional dia.))</td>
</tr>
<tr class="row-8">
<td class="column-1">Key Ring End Cap</td>
<td class="column-2">Key ring replaces standard bottom<br />
Thru-hole: 0.150&#8243;</td>
</tr>
<tr class="row-9">
<td class="column-1">IP Rating</td>
<td class="column-2">IP68</td>
</tr>
<tr class="row-10">
<td class="column-1">Submersible</td>
<td class="column-2">Yes</td>
</tr>
<tr class="row-11">
<td class="column-1">Operating Environment</td>
<td class="column-2">-40 °C to +140 °C (-40 °F to +284 °F); 0 %RH to 100 %RH; 0.002 PSIA to 100 PSIA <strong>(Body of Logger Cannot Exceed 140 °C)</strong></td>
</tr>
<tr class="row-12">
<td class="column-1">Required Interface Package</td>
<td class="column-2">IFC400</td>
</tr>
<tr class="row-13">
<td class="column-1">Approvals</td>
<td class="column-2">CE</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<div id="" class="specs-table-wrapper">
<h3>Temperature</h3>
<table id="tablepress-hitemp140-temperature-no-2" class="tablepress tablepress-id-hitemp140-temperature">
<tbody>
<tr class="row-1">
<td class="column-1">Temperature Sensor</td>
<td class="column-2">100 Ω Platinum RTD</td>
</tr>
<tr class="row-2">
<td class="column-1">Temperature Resolution</td>
<td class="column-2">0.01 °C (0.018 °F)</td>
</tr>
<tr class="row-3">
<td class="column-1">Temperature Calibrated Accuracy</td>
<td class="column-2">±0.1 °C/±0.18 °F (20 °C to +140 °C/68 °F to +284 °F)<br />
±0.3 °C/±0.54 °F (-20 °C to +19.99 °C/-4 °F to +67.98 °F)<br />
±0.4 °C/±0.72 ºF (-40 °C to -20.01 °C/-40 °F to +-4.02 °F)</td>
</tr>
<tr class="row-4">
<td class="column-1">Probe Temperature Range</td>
<td class="column-2">-200 °C to +260 °C (-328 °F to +500 °F) <strong>(Body of Logger Cannot Exceed 140 °C)</strong></td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://ieslbd.com/service/hitemp140/">HiTemp140</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/hitemp140/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>NanoTemp125</title>
		<link>https://ieslbd.com/service/nanotemp125/</link>
					<comments>https://ieslbd.com/service/nanotemp125/#respond</comments>
		
		<dc:creator><![CDATA[Md. Yousuf]]></dc:creator>
		<pubDate>Tue, 28 Oct 2025 12:16:29 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12489</guid>

					<description><![CDATA[<p>The NanoTemp125 is a miniature, rugged high-temperature data logger built for demanding environments. It features a compact stainless-steel body, is fully submersible (IP68), and operates over a wide temperature range (-20 °C to +125 °C) with high precision (±0.1 °C in its optimal range). It stores over 32,000 time- and date-stamped readings and is designed to fit into tight spaces (such as autoclaves, vials, and other constrained environments) while still offering trusted performance.</p>
<p>The post <a href="https://ieslbd.com/service/nanotemp125/">NanoTemp125</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The NanoTemp125 is a miniature high-temperature data logger. Includes ISO17025 accredited calibration certificate and two replacement batteries.</p>
<p>Key Features:</p>
<ul>
<li>Compact Size</li>
<li>Submersible</li>
<li>Available in Various Probe Lengths</li>
<li>Measures Temperatures from -20 °C to +125 °C</li>
</ul>
<p>The NanoTemp125 is the newest innovation in MadgeTech’s high-temperature data logging lineup, offering the same trusted performance as the <a href="https://www.madgetech.com/products/hitemp140/">HiTemp140</a> series in a significantly smaller design. Specifically crafted for space-constrained applications, this submersible, stainless steel data logger is ideal for industries requiring reliable, high-precision temperature monitoring. From autoclave validations to pharmaceutical manufacturing and food processing, the NanoTemp125 is built to thrive in the most demanding environments.</p>
<p>The NanoTemp125 operates within a temperature range of -20 °C to +125 °C (-4 °F to +257 °F), providing exceptional versatility for both high-temperature and cryogenic applications. Its compact size allows it to fit effortlessly into tight spaces, making it perfect for autoclave chambers, small vials, and other challenging environments. Despite its size, the NanoTemp125 delivers an impressive accuracy of ±0.1 °C (±0.18 °F), ensuring the precision required for regulatory compliance and quality assurance.</p>
<p>Equipped with the capacity to store more than 32,000 time- and date-stamped readings, the NanoTemp125 can monitor processes over extended periods without interruption. Its rugged, waterproof design ensures durability and reliability in wet and dry applications alike, making it a valuable tool for diverse monitoring needs.</p>
<p>The NanoTemp125 is fully compatible with MadgeTech 4 Data Logger Software, enabling easy setup, seamless data management, and detailed analysis. Whether conducting autoclave validations or monitoring temperature in other critical processes, the NanoTemp125 combines compact convenience with trusted performance to meet your most challenging demands.</p>
<h2>MadgeTech <strong>NanoTemp125</strong> — Specification Overview</h2>
<p>Here are the key technical specifications for the NanoTemp125 miniature high-temperature data logger:</p>
<h3>Temperature &amp; Sensor</h3>
<ul>
<li>Sensor type: Internal RTD (100 Ω platinum) (<a title="NanoTemp125-CF" href="https://www.madgetech.com/wp-content/uploads/2025/04/DOC-1454009-00.pdf?utm_source=chatgpt.com">madgetech.com</a>)</li>
<li>Probe measurement range: –200 °C to +260 °C (-328 °F to +500 °F) (<a title="MadgeTech NanoTemp125 | Miniature high-temperature data logger - Pacific Sensor Tech" href="https://www.pacificsensortech.com.au/nanotemp125?utm_source=chatgpt.com">Pacific Sensor Technologies</a>)</li>
<li>Operating (body) temperature range: –20 °C to +125 °C (-4 °F to +257 °F) (<a title="NanoTemp125 | High Temperature Data Logger | MadgeTech" href="https://www.madgetech.com/products/nanotemp125/?utm_source=chatgpt.com">madgetech.com</a>)</li>
<li>Temperature resolution: 0.01 °C (0.02 °F) (<a title="NanoTemp125" href="https://www.krone.co.jp/pdf/madgetech/NanoTemp125.pdf?utm_source=chatgpt.com">krone.co.jp</a>)</li>
<li>Calibrated accuracy:
<ul>
<li>±0.1 °C (±0.18 °F) for 20 °C to +125 °C (68 °F to 257 °F) (<a title="MadgeTech NanoTemp125 | Miniature high-temperature data logger - Pacific Sensor Tech" href="https://www.pacificsensortech.com.au/nanotemp125?utm_source=chatgpt.com">Pacific Sensor Technologies</a>)</li>
<li>±0.3 °C (±0.54 °F) for –20 °C to +19.99 °C (-4 °F to +67.98 °F) (<a title="소형 고온 데이터로거 &gt; 온도 로거 | 테솔" href="https://www.tessol.com/shop/1744864418?utm_source=chatgpt.com">tessol.com</a>)</li>
</ul>
</li>
</ul>
<h3>Memory &amp; Logging</h3>
<ul>
<li>Memory capacity: 32,512 readings (<a title="NanoTemp125" href="https://www.madgetech.com/wp-content/uploads/2025/01/DOC-1452009-00-1.pdf?utm_source=chatgpt.com">madgetech.com</a>)</li>
<li>Reading rate: from 1 reading every 1 second up to 1 reading every 24 hours (<a title="NanoTemp125-CF" href="https://www.madgetech.com/wp-content/uploads/2025/04/DOC-1454009-00.pdf?utm_source=chatgpt.com">madgetech.com</a>)</li>
<li>Trigger settings: High/Low limit triggers, bi-level start/stop triggers supported (<a title="MadgeTech NanoTemp125 | Miniature high-temperature data logger - Pacific Sensor Tech" href="https://www.pacificsensortech.com.au/nanotemp125?utm_source=chatgpt.com">Pacific Sensor Technologies</a>)</li>
<li>Wrap around: Yes (<a title="NanoTemp125-CF" href="https://www.madgetech.com/wp-content/uploads/2025/04/DOC-1454009-00.pdf?utm_source=chatgpt.com">madgetech.com</a>)</li>
</ul>
<h3>Physical / Mechanical</h3>
<ul>
<li>Body dimensions: 22.9 mm height × 17.8 mm diameter (<a title="NanoTemp125" href="https://www.krone.co.jp/pdf/madgetech/NanoTemp125.pdf?utm_source=chatgpt.com">krone.co.jp</a>)</li>
<li>Probe diameter: typically 3.2 mm (4.8 mm trans. dia) for standard models (<a title="NanoTemp125" href="https://www.krone.co.jp/pdf/madgetech/NanoTemp125.pdf?utm_source=chatgpt.com">krone.co.jp</a>)</li>
<li>Probe lengths: multiple options, e.g.:
<ul>
<li>NanoTemp125-1: 25.4 mm (1.0 in) length (<a title="NanoTemp125" href="https://www.krone.co.jp/pdf/madgetech/NanoTemp125.pdf?utm_source=chatgpt.com">krone.co.jp</a>)</li>
<li>NanoTemp125-2: 50.8 mm length (<a title="超小型耐熱温度データロガー NanoTemp125 (高精度、耐圧防水、ISO/IEC17025校正証明書付)" href="https://www.mksci.com/products/detail/1412.html?utm_source=chatgpt.com">mksci.com</a>)</li>
<li>NanoTemp125-5 (or 5.25 in): 133.35 mm length (<a title="MadgeTech NanoTemp125-5.25 Miniature High Temperature Data Logger with 5.25&quot; probe" href="https://www.itm.com/product/madgetech-nanotemp125-5-25-miniature-high-temperature-data-logger-902461-00?utm_source=chatgpt.com">ITM</a>)</li>
</ul>
</li>
<li>Weight approx: 18–20 g depending on probe length/model (<a title="MadgeTech NanoTemp125 | Miniature high-temperature data logger - Pacific Sensor Tech" href="https://www.pacificsensortech.com.au/nanotemp125?utm_source=chatgpt.com">Pacific Sensor Technologies</a>)</li>
<li>Material: 316 stainless steel body, PEEK components (<a title="NanoTemp125" href="https://www.krone.co.jp/pdf/madgetech/NanoTemp125.pdf?utm_source=chatgpt.com">krone.co.jp</a>)</li>
<li>Ingress protection: IP68 (fully submersible) (<a title="NanoTemp125" href="https://www.madgetech.com/wp-content/uploads/2025/01/DOC-1452009-00-1.pdf?utm_source=chatgpt.com">madgetech.com</a>)</li>
</ul>
<h3>Power &amp; Interface</h3>
<ul>
<li>Battery type: Two 3 V high-temperature lithium coin cells, user-replaceable (<a title="NanoTemp125-CF" href="https://www.madgetech.com/wp-content/uploads/2025/04/DOC-1454009-00.pdf?utm_source=chatgpt.com">madgetech.com</a>)</li>
<li>Typical battery life: ~1 year (assuming 1-minute read interval at 25 °C) (<a title="超小型耐熱温度データロガー NanoTemp125 (高精度、耐圧防水、ISO/IEC17025校正証明書付)" href="https://www.mksci.com/products/detail/1412.html?utm_source=chatgpt.com">mksci.com</a>)</li>
<li>Time accuracy: ±1 minute/month (20 °C to 30 °C) in stand-alone mode (<a title="NanoTemp125-CF" href="https://www.madgetech.com/wp-content/uploads/2025/04/DOC-1454009-00.pdf?utm_source=chatgpt.com">madgetech.com</a>)</li>
<li>Computer interface: Requires USB docking station (e.g., IFC400 or IFC406) with adapter; baud rate 125,000 (<a title="MadgeTech NanoTemp125 | Miniature high-temperature data logger - Pacific Sensor Tech" href="https://www.pacificsensortech.com.au/nanotemp125?utm_source=chatgpt.com">Pacific Sensor Technologies</a>)</li>
<li>Software compatibility: Works with MadgeTech 4 Standard/Secure software versions noted in datasheet (<a title="NanoTemp125" href="https://www.madgetech.com/wp-content/uploads/2025/01/DOC-1452009-00-1.pdf?utm_source=chatgpt.com">madgetech.com</a>)</li>
</ul>
<h3>Environmental / Other</h3>
<ul>
<li>Operating environment: –20 °C to +125 °C, 0 % RH to 100 % RH, 0.002 PSIA to 100 PSIA (<a title="MadgeTech NanoTemp125 | Miniature high-temperature data logger - Pacific Sensor Tech" href="https://www.pacificsensortech.com.au/nanotemp125?utm_source=chatgpt.com">Pacific Sensor Technologies</a>)</li>
<li>Probes and variants for different applications (for example, the “CF” version for canning/sterilization) (<a title="NanoTemp125-CF" href="https://www.madgetech.com/wp-content/uploads/2025/04/DOC-1454009-00.pdf?utm_source=chatgpt.com">madgetech.com</a>)</li>
</ul>
<p>&nbsp;</p>
<p>The post <a href="https://ieslbd.com/service/nanotemp125/">NanoTemp125</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/nanotemp125/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>RFTCTemp2000A</title>
		<link>https://ieslbd.com/service/rftctemp2000a/</link>
					<comments>https://ieslbd.com/service/rftctemp2000a/#respond</comments>
		
		<dc:creator><![CDATA[Md. Yousuf]]></dc:creator>
		<pubDate>Tue, 28 Oct 2025 12:16:26 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12491</guid>

					<description><![CDATA[<p>The RFTCTemp2000A is a <strong data-start="77" data-end="132">wireless thermocouple-based temperature data logger</strong> designed for ambient and remote temperature monitoring via interchangeable thermocouples (types J, K, T, E, R, S, B, N).<br data-start="291" data-end="294" />It features an LCD display showing current reading, min/max/average stats, supports configurable alarms (LED, audible, email/SMS alerts), and integrates with the MadgeTech 4 software (and cloud services) for real-time or periodic data download.</p>
<p>The post <a href="https://ieslbd.com/service/rftctemp2000a/">RFTCTemp2000A</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The RFTCTemp2000A is a wireless thermocouple-based temperature data logger. Includes ISO 17025 accredited calibration certificate.</p>
<p>Key Features:</p>
<ul>
<li>Digital Display</li>
<li>Continuous Monitoring</li>
<li>Configurable Alarms &amp; Notifications</li>
</ul>
<p>The RFTCTemp2000A is a wireless thermocouple-based temperature data logger <em>(probe sold separately). </em>Ideal for monitoring ambient and remote temperature, the RFTCTemp2000A accepts a variety of thermocouples and is designed with a built-in temperature sensor for cold junction compensation.</p>
<p>This device features an LCD screen which provides instant access to current readings, minimum, maximum and average statistics. Equipped with user-programmable alarms, the RFTCTemp2000A will alert or notify users via email or text when thresholds are breached, allowing users to take immediate action.The RFTCTemp2000A is available with mini-plug (RFTCTemp2000A-MP) or terminal block (RFTCTemp2000A-TB) connector.</p>
<p>The RFTCTemp2000A is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.</p>
<p>The RFTCTemp2000A is also MadgeTech Cloud Services ready, providing users the ability to monitor data remotely on any smartphone, tablet or internet enabled device.</p>
<h1>Specifications</h1>
<div id="" class="specs-table-wrapper">
<h4>General</h4>
<table id="tablepress-rftctemp2000a-general-no-3" class="tablepress tablepress-id-rftctemp2000a-general">
<tbody>
<tr class="row-1">
<td class="column-1">Memory</td>
<td class="column-2">16,128 readings</td>
</tr>
<tr class="row-2">
<td class="column-1">Reading Rate</td>
<td class="column-2">1 reading every second up to 1 reading every 24 hours</td>
</tr>
<tr class="row-3">
<td class="column-1">Baud Rate</td>
<td class="column-2">250,000</td>
</tr>
<tr class="row-4">
<td class="column-1">LED Indicators</td>
<td class="column-2">Green, Blue &amp; Red</td>
</tr>
<tr class="row-5">
<td class="column-1">Battery Life</td>
<td class="column-2">3 years typical at a 1 minute reading rate</td>
</tr>
<tr class="row-6">
<td class="column-1">Material</td>
<td class="column-2">ABS plastic</td>
</tr>
<tr class="row-7">
<td class="column-1">Dimensions</td>
<td class="column-2">3.0 in x 3.5 in x 0.95 in (76.2 mm x 88.9 mm x 24.1 mm) &#8211; Data logger only</td>
</tr>
<tr class="row-8">
<td class="column-1">IP Rating</td>
<td class="column-2">IP22</td>
</tr>
<tr class="row-9">
<td class="column-1">Operating Environment</td>
<td class="column-2">-20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing</td>
</tr>
<tr class="row-10">
<td class="column-1">Required Interface Package</td>
<td class="column-2">RFC1000</td>
</tr>
<tr class="row-11">
<td class="column-1">Approvals</td>
<td class="column-2">US (FCC), CA (IC), CE, South Korea (KCC), China (CMIIT), Japan (LCIE)</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<div id="" class="specs-table-wrapper">
<h4>Temperature</h4>
<table id="tablepress-rftctemp2000a-temperature-no-2" class="tablepress tablepress-id-rftctemp2000a-temperature">
<tbody>
<tr class="row-1">
<td class="column-1">External Temperature Sensor</td>
<td class="column-2">Thermocouple types: J, K, T, E, R, S, B, N</td>
</tr>
<tr class="row-2">
<td class="column-1">External Temperature Range</td>
<td class="column-2">-210 °C to +1300 °C (-410 °F to +2372 °F) <i>(Probe Dependent)</i></td>
</tr>
<tr class="row-3">
<td class="column-1">External Temperature Resolution</td>
<td class="column-2">0.1 °C (0.18 °F) <i>(Probe Dependent)</i></td>
</tr>
<tr class="row-4">
<td class="column-1">External Temperature Calibrated Accuracy</td>
<td class="column-2">±0.5 °C (± 0.9 °F) <i>(Probe Dependent)</i></td>
</tr>
<tr class="row-5">
<td class="column-1">Internal Temperature Sensor</td>
<td class="column-2">Internal Semiconductor</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<div id="" class="specs-table-wrapper">
<h4>Wireless</h4>
<table id="tablepress-rftctemp2000a-wireless-no-2" class="tablepress tablepress-id-rftctemp2000a-wireless">
<tbody>
<tr class="row-1">
<td class="column-1">RF Carrier Frequency</td>
<td class="column-2">2.45 GHz IEEE 802.15.4 ultra-low power MadgeNET Wireless Transceiver with fully by-directional communication.</td>
</tr>
<tr class="row-2">
<td class="column-1">Output Power</td>
<td class="column-2">+0 dBm typical</td>
</tr>
<tr class="row-3">
<td class="column-1">Receiver Sensitivity</td>
<td class="column-2">-95 dBm typical</td>
</tr>
<tr class="row-4">
<td class="column-1">Typical outdoors Line of sight</td>
<td class="column-2">Up to 2000 ft</td>
</tr>
<tr class="row-5">
<td class="column-1">Typical Indoors line of sight</td>
<td class="column-2">Up to 500 ft</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://ieslbd.com/service/rftctemp2000a/">RFTCTemp2000A</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/rftctemp2000a/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>AVS140-1</title>
		<link>https://ieslbd.com/service/avs140-1/</link>
					<comments>https://ieslbd.com/service/avs140-1/#respond</comments>
		
		<dc:creator><![CDATA[Md. Yousuf]]></dc:creator>
		<pubDate>Tue, 28 Oct 2025 12:15:21 +0000</pubDate>
				<guid isPermaLink="false">https://ieslbd.com/?post_type=product&#038;p=12493</guid>

					<description><![CDATA[<p data-start="95" data-end="487">The AVS140-1 is a complete validation kit designed for steam sterilizers (autoclaves). It includes a high-temperature data logger (HiTemp140) with a 1″ probe and NIST-traceable calibration, a USB interface cable (IFC400) and the MadgeTech 4 Secure software bundle which supports FDA 21 CFR Part 11 compliance (audit trail, electronic signatures, etc.).</p>
<p data-start="494" data-end="765">The logger within the kit is built for harsh environments: stainless-steel construction, submersible (IP68 rated), and works in high-temperature environments (body up to +140 °C/284 °F, probe measurement range to ~-200 to +260 °C)</p>
<p>The post <a href="https://ieslbd.com/service/avs140-1/">AVS140-1</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The AVS140-1 is a complete system for performing autoclave validations and assisting users with 21 CFR Part 11 compliance. Includes ISO17025 accredited calibration certificate.</p>
<p>Key Features:</p>
<ul>
<li>HiTemp140 High Temperature Data Logger</li>
<li>IFC400 Interface Cable</li>
<li>MadgeTech Secure Data Logger Software</li>
</ul>
<p>The AVS140-1 Includes:<br />
(1) HiTemp140: High Temperature Data Logger with 1 in. Probe and Calibration Certificate<br />
(1) IFC400: Interface Cable<br />
(1) MadgeTech Secure Data Logger Software<strong>: </strong>Complete with IQ/OQ/PQ Validation Protocols and Workbook</p>
<p>The HiTemp140 is a high precision, temperature data logger built for use in harsh environments. This stainless steel device is submersible and can withstand temperatures up to 140 °C (284 °F) with an accuracy of ±0.1 °C (0.18 °F).</p>
<p>The MadgeTech 4 Secure Software aids customers in compliance with 21 CFR Part 11 requirements, ensuring standards in which electronic files are considered equivalent to paper records, saving time and effort. MadgeTech 4 Secure Software contains criteria such as electronic signatures, access codes, secure data files, and an audit trail to meet requirements while providing data integrity.</p>
<p>The post <a href="https://ieslbd.com/service/avs140-1/">AVS140-1</a> appeared first on <a href="https://ieslbd.com">Instrumentation Engineering Services Ltd.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ieslbd.com/service/avs140-1/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
