Description
Chilled mirror hygrometry is a precise technique for determining the water vapor content is gases by directly measuring dew point or frost temperatures. Using this technique a metal mirror is cooled until it reaches a temperature at which a thin layer of condensation begins to form on it. The dew layer is detected optically, and the mirror is held at that temperature. The mirror temperature, measures with a PRT, is an accurate indicator of the dew or frost point.
FEATURES
- Dew point measure range -40℃ to +90℃
- Accuracy of dew point is ±0.15 ℃
- Dynamic balance control for contamination
- Simultaneously measures dew point, temperature, relative humidity, absolute humidity, specific humidity, enthalpy, vapor pressure and volume ratio (ppmV).
- Real time data logging and display curve
- MAX value and MIN value are recorded
- AC or alternative DC power supply
- MODBUS RTU and USB communication
- 4 Inch touch screen
- External temperature sensor port
- Force frost function at low dew points
APPLICATION
- Reference standard in calibration lab
- Inlet air measurement for engine testing
- Heating ventilation and air conditioning test
- Environment monitoring in clean room
- Humidity control for metallurgical processes
- Coating process monitoring in pharmacy
- Reference humidity instruments for climatic and environmental chambers
SPECIFICATION
- DP/FP ranges: -40℃ to +90℃, (0.55%~100%RH @20℃)
DP/FP accuracy: ±0.15℃ (calibration: -15℃ to +20℃)
DP/FP resolution: 0.01℃
DP/FP reproducibility error: ±0.05℃
- Temperature range: -45℃ to +100℃
Temperature accuracy: ±0.05℃ (calibration: -10℃~60℃)
Temperature resolution: 0.01℃
Temperature reproducibility error: ±0.05℃
- Working environment: -20℃ to +60℃, 10%RH to 90%RH, 101.325kPa (custom atm. is option)
- Mirror temperature measurement: 4 wire PT100 1/3B
- Probe material: SUS304 stainless steel
- Cable material: Polyurethane material with shielding layer
- Response time: Max cooling 0.8℃/s, + 15s balance time
- Sampling airflow rate: 0.1~1NL/min (The volume of ventilation is inversely proportional to the dew point)
- Cooling type: Peltier cooling
- Output signal: Modbus RTU, USB
- Power supply: 100-240V AC 35W or USB Type-C 5V/2A 10W
- Ingress protection grade: IP54
- Dimension: 160mm (W) x 165mm (D) x 85mm (H)
- Weight: 4kg inlcudes standard accessories
SCOPE OF DELIVERY
- BL783 Precision chilled mirror hygrometer
- Two Stage Chilled Mirror Dew Point Sensor
- Temperature sensor
- 2 meters dew point sensor connection cable
- 2 meters temperature sensor connection cable
- USB2.0 into USB type-C cable
- Standard AC Power cord
- User manual
- Factory calibration report
- Carrying case
OPTIONAL ACCESSORIES AND SERVICES
- ISO17025 accredited calibration certificate
HOW TO ORDER
- BL783-220V
- BL783-110V